{"product_id":"siemens-6sl3100-1ae31-0ab1-line-reactor-500v-36kw","title":"Siemens 6SL3100-1AE31-0AB1","description":"\u003cp data-end=\"855\" data-start=\"506\"\u003eThe Siemens 6SL3100-1AE31-0AB1 is a SINAMICS S120 line reactor designed to reduce harmonics, protect input circuits, and enhance power quality in 500 V three-phase systems. Ideal for integration with SINAMICS S120 drives, this reactor improves the electromagnetic compatibility (EMC) and extends equipment lifespan under harsh industrial conditions.\u003c\/p\u003e\n\u003ch3 data-end=\"877\" data-start=\"857\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul data-end=\"1198\" data-start=\"879\"\u003e\n\u003cli data-end=\"921\" data-start=\"879\"\u003e\n\u003cp data-end=\"921\" data-start=\"881\"\u003eLine reactor for SINAMICS S120 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"969\" data-start=\"922\"\u003e\n\u003cp data-end=\"969\" data-start=\"924\"\u003eRated for 3-phase 500 V, 36 kW applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1019\" data-start=\"970\"\u003e\n\u003cp data-end=\"1019\" data-start=\"972\"\u003eReduces current harmonics and inrush currents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1069\" data-start=\"1020\"\u003e\n\u003cp data-end=\"1069\" data-start=\"1022\"\u003eProtects the inverter and upstream components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1121\" data-start=\"1070\"\u003e\n\u003cp data-end=\"1121\" data-start=\"1072\"\u003eEnhances system reliability and EMC performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1157\" data-start=\"1122\"\u003e\n\u003cp data-end=\"1157\" data-start=\"1124\"\u003eCompact and rugged construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1198\" data-start=\"1158\"\u003e\n\u003cp data-end=\"1198\" data-start=\"1160\"\u003eEasy integration into control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1232\" data-start=\"1200\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul data-end=\"1743\" data-start=\"1234\"\u003e\n\u003cli data-end=\"1274\" data-start=\"1234\"\u003e\n\u003cp data-end=\"1274\" data-start=\"1236\"\u003e\u003cstrong data-end=\"1253\" data-start=\"1236\"\u003eSiemens Code:\u003c\/strong\u003e 6SL3100-1AE31-0AB1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1309\" data-start=\"1275\"\u003e\n\u003cp data-end=\"1309\" data-start=\"1277\"\u003e\u003cstrong data-end=\"1294\" data-start=\"1277\"\u003eProduct Type:\u003c\/strong\u003e Line Reactor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1339\" data-start=\"1310\"\u003e\n\u003cp data-end=\"1339\" data-start=\"1312\"\u003e\u003cstrong data-end=\"1323\" data-start=\"1312\"\u003eSeries:\u003c\/strong\u003e SINAMICS S120\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1373\" data-start=\"1340\"\u003e\n\u003cp data-end=\"1373\" data-start=\"1342\"\u003e\u003cstrong data-end=\"1361\" data-start=\"1342\"\u003eVoltage Rating:\u003c\/strong\u003e 3AC 500 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1401\" data-start=\"1374\"\u003e\n\u003cp data-end=\"1401\" data-start=\"1376\"\u003e\u003cstrong data-end=\"1393\" data-start=\"1376\"\u003ePower Rating:\u003c\/strong\u003e 36 kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1457\" data-start=\"1402\"\u003e\n\u003cp data-end=\"1457\" data-start=\"1404\"\u003e\u003cstrong data-end=\"1419\" data-start=\"1404\"\u003eInductance:\u003c\/strong\u003e Optimized for drive input filtering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1498\" data-start=\"1458\"\u003e\n\u003cp data-end=\"1498\" data-start=\"1460\"\u003e\u003cstrong data-end=\"1477\" data-start=\"1460\"\u003eCooling Type:\u003c\/strong\u003e Natural convection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1553\" data-start=\"1499\"\u003e\n\u003cp data-end=\"1553\" data-start=\"1501\"\u003e\u003cstrong data-end=\"1523\" data-start=\"1501\"\u003eProtection Rating:\u003c\/strong\u003e IP00 (for cabinet mounting)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1610\" data-start=\"1554\"\u003e\n\u003cp data-end=\"1610\" data-start=\"1556\"\u003e\u003cstrong data-end=\"1573\" data-start=\"1556\"\u003eInstallation:\u003c\/strong\u003e Vertical mounting in control panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1638\" data-start=\"1611\"\u003e\n\u003cp data-end=\"1638\" data-start=\"1613\"\u003e\u003cstrong data-end=\"1627\" data-start=\"1613\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1686\" data-start=\"1639\"\u003e\n\u003cp data-end=\"1686\" data-start=\"1641\"\u003e\u003cstrong data-end=\"1667\" data-start=\"1641\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +40 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1743\" data-start=\"1687\"\u003e\n\u003cp data-end=\"1743\" data-start=\"1689\"\u003e\u003cstrong data-end=\"1708\" data-start=\"1689\"\u003eCertifications:\u003c\/strong\u003e CE, RoHS, UL (depending on region)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1765\" data-start=\"1745\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul data-end=\"2003\" data-start=\"1767\"\u003e\n\u003cli data-end=\"1817\" data-start=\"1767\"\u003e\n\u003cp data-end=\"1817\" data-start=\"1769\"\u003eHarmonic filtering in industrial drive systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1866\" data-start=\"1818\"\u003e\n\u003cp data-end=\"1866\" data-start=\"1820\"\u003eInput protection for SINAMICS S120 inverters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1905\" data-start=\"1867\"\u003e\n\u003cp data-end=\"1905\" data-start=\"1869\"\u003eMachine tools and automation lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1948\" data-start=\"1906\"\u003e\n\u003cp data-end=\"1948\" data-start=\"1908\"\u003eHVAC systems and conveyor applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2003\" data-start=\"1949\"\u003e\n\u003cp data-end=\"2003\" data-start=\"1951\"\u003eEnergy-efficient installations requiring clean power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2051\" data-start=\"2005\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose Siemens 6SL3100-1AE31-0AB1?:\u003c\/h3\u003e\n\u003cul data-end=\"2302\" data-start=\"2053\"\u003e\n\u003cli data-end=\"2103\" data-start=\"2053\"\u003e\n\u003cp data-end=\"2103\" data-start=\"2055\"\u003eMinimizes harmonics and enhances power quality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2143\" data-start=\"2104\"\u003e\n\u003cp data-end=\"2143\" data-start=\"2106\"\u003eProtects valuable drive electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2194\" data-start=\"2144\"\u003e\n\u003cp data-end=\"2194\" data-start=\"2146\"\u003eDesigned specifically for SINAMICS S120 drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2246\" data-start=\"2195\"\u003e\n\u003cp data-end=\"2246\" data-start=\"2197\"\u003eReliable Siemens engineering for industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2302\" data-start=\"2247\"\u003e\n\u003cp data-end=\"2302\" data-start=\"2249\"\u003eCompact solution for space-constrained control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48885370487011,"sku":"6SL3100-1AE31-0AB1","price":1286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/6SL3100-1AE31-0AB1.webp?v=1777402952","url":"https:\/\/flateck.myshopify.com\/pt\/products\/siemens-6sl3100-1ae31-0ab1-line-reactor-500v-36kw","provider":"Flateck Automation","version":"1.0","type":"link"}