{"product_id":"siemens-6sl3055-0aa00-3aa1-line-reactor-400v-55a","title":"Siemens 6SL3055-0AA00-3AA1","description":"\u003cp data-end=\"785\" data-start=\"508\"\u003eThe Siemens 6SL3055-0AA00-3AA1 is a line reactor designed for use with SINAMICS G120 frequency converters. Supporting 3-phase 400 V systems with up to 55 A, it reduces current harmonics, improves power quality, and extends the service life of the drive and connected equipment.\u003c\/p\u003e\n\u003ch3 data-end=\"807\" data-start=\"787\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul data-end=\"1165\" data-start=\"809\"\u003e\n\u003cli data-end=\"851\" data-start=\"809\"\u003e\n\u003cp data-end=\"851\" data-start=\"811\"\u003eLine reactor for SINAMICS G120 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"881\" data-start=\"852\"\u003e\n\u003cp data-end=\"881\" data-start=\"854\"\u003eRated for 3AC 400 V, 55 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"948\" data-start=\"882\"\u003e\n\u003cp data-end=\"948\" data-start=\"884\"\u003eReduces harmonic distortion and protects against voltage peaks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1002\" data-start=\"949\"\u003e\n\u003cp data-end=\"1002\" data-start=\"951\"\u003eEnhances system reliability and energy efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1040\" data-start=\"1003\"\u003e\n\u003cp data-end=\"1040\" data-start=\"1005\"\u003eMinimizes motor noise and heating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1089\" data-start=\"1041\"\u003e\n\u003cp data-end=\"1089\" data-start=\"1043\"\u003eImproves electromagnetic compatibility (EMC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1140\" data-start=\"1090\"\u003e\n\u003cp data-end=\"1140\" data-start=\"1092\"\u003eIncreases service life of frequency converters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1165\" data-start=\"1141\"\u003e\n\u003cp data-end=\"1165\" data-start=\"1143\"\u003eEasy DIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1199\" data-start=\"1167\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul data-end=\"1636\" data-start=\"1201\"\u003e\n\u003cli data-end=\"1241\" data-start=\"1201\"\u003e\n\u003cp data-end=\"1241\" data-start=\"1203\"\u003e\u003cstrong data-end=\"1220\" data-start=\"1203\"\u003eSiemens Code:\u003c\/strong\u003e 6SL3055-0AA00-3AA1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1278\" data-start=\"1242\"\u003e\n\u003cp data-end=\"1278\" data-start=\"1244\"\u003e\u003cstrong data-end=\"1263\" data-start=\"1244\"\u003eComponent Type:\u003c\/strong\u003e Line Reactor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1325\" data-start=\"1279\"\u003e\n\u003cp data-end=\"1325\" data-start=\"1281\"\u003e\u003cstrong data-end=\"1297\" data-start=\"1281\"\u003eApplication:\u003c\/strong\u003e Input side (line reactor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1364\" data-start=\"1326\"\u003e\n\u003cp data-end=\"1364\" data-start=\"1328\"\u003e\u003cstrong data-end=\"1347\" data-start=\"1328\"\u003eVoltage Rating:\u003c\/strong\u003e 3AC 400 V ±10%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1393\" data-start=\"1365\"\u003e\n\u003cp data-end=\"1393\" data-start=\"1367\"\u003e\u003cstrong data-end=\"1386\" data-start=\"1367\"\u003eCurrent Rating:\u003c\/strong\u003e 55 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1421\" data-start=\"1394\"\u003e\n\u003cp data-end=\"1421\" data-start=\"1396\"\u003e\u003cstrong data-end=\"1410\" data-start=\"1396\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1461\" data-start=\"1422\"\u003e\n\u003cp data-end=\"1461\" data-start=\"1424\"\u003e\u003cstrong data-end=\"1437\" data-start=\"1424\"\u003eMounting:\u003c\/strong\u003e DIN rail or baseplate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1492\" data-start=\"1462\"\u003e\n\u003cp data-end=\"1492\" data-start=\"1464\"\u003e\u003cstrong data-end=\"1485\" data-start=\"1464\"\u003eProtection Class:\u003c\/strong\u003e IP00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1535\" data-start=\"1493\"\u003e\n\u003cp data-end=\"1535\" data-start=\"1495\"\u003e\u003cstrong data-end=\"1514\" data-start=\"1495\"\u003eCooling Method:\u003c\/strong\u003e Natural convection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1583\" data-start=\"1536\"\u003e\n\u003cp data-end=\"1583\" data-start=\"1538\"\u003e\u003cstrong data-end=\"1564\" data-start=\"1538\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +40 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1636\" data-start=\"1584\"\u003e\n\u003cp data-end=\"1636\" data-start=\"1586\"\u003e\u003cstrong data-end=\"1608\" data-start=\"1586\"\u003eCompatible Drives:\u003c\/strong\u003e SINAMICS G120 Power Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1658\" data-start=\"1638\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul data-end=\"1841\" data-start=\"1660\"\u003e\n\u003cli data-end=\"1700\" data-start=\"1660\"\u003e\n\u003cp data-end=\"1700\" data-start=\"1662\"\u003eSINAMICS G120 drive input protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1733\" data-start=\"1701\"\u003e\n\u003cp data-end=\"1733\" data-start=\"1703\"\u003eIndustrial automation panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1771\" data-start=\"1734\"\u003e\n\u003cp data-end=\"1771\" data-start=\"1736\"\u003ePump, fan, and compressor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1803\" data-start=\"1772\"\u003e\n\u003cp data-end=\"1803\" data-start=\"1774\"\u003eMotor control centers (MCC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1841\" data-start=\"1804\"\u003e\n\u003cp data-end=\"1841\" data-start=\"1806\"\u003eSystems requiring reduced harmonics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1889\" data-start=\"1843\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose Siemens 6SL3055-0AA00-3AA1?:\u003c\/h3\u003e\n\u003cul data-end=\"2131\" data-start=\"1891\"\u003e\n\u003cli data-end=\"1947\" data-start=\"1891\"\u003e\n\u003cp data-end=\"1947\" data-start=\"1893\"\u003eImproves drive reliability and electrical protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1999\" data-start=\"1948\"\u003e\n\u003cp data-end=\"1999\" data-start=\"1950\"\u003eEnsures compliance with power quality standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2043\" data-start=\"2000\"\u003e\n\u003cp data-end=\"2043\" data-start=\"2002\"\u003eReduces electrical stress on components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2088\" data-start=\"2044\"\u003e\n\u003cp data-end=\"2088\" data-start=\"2046\"\u003eSimple integration into control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2131\" data-start=\"2089\"\u003e\n\u003cp data-end=\"2131\" data-start=\"2091\"\u003eSiemens quality and long-term durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48885365047523,"sku":"6SL3055-0AA00-3AA1","price":838.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/6SL3055-0AA00-3AA1.webp?v=1777402900","url":"https:\/\/flateck.myshopify.com\/pt\/products\/siemens-6sl3055-0aa00-3aa1-line-reactor-400v-55a","provider":"Flateck Automation","version":"1.0","type":"link"}