{"product_id":"pepperl-fuchs-vba-4e4a-g12-zaj-ea2l-as-interface-module-4-pnp-inputs","title":"Pepperl+Fuchs VBA-4E4A-G12-ZAJ\/EA2L","description":"\u003cp\u003eThe \u003cstrong\u003ePepperl+Fuchs VBA-4E4A-G12-ZAJ\/EA2L\u003c\/strong\u003e is a robust \u003cstrong\u003eAS-Interface sensor\/actuator module\u003c\/strong\u003e designed to facilitate seamless integration of sensors and actuators into AS-Interface networks. With \u003cstrong\u003e4 PNP inputs\u003c\/strong\u003e and \u003cstrong\u003e4 electronic outputs\u003c\/strong\u003e, this module is engineered for reliable performance in industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e 4 inputs for 2- or 3-wire sensors (PNP, DC); option for 2 inputs for 4-wire sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e 4 electronic outputs, PNP, overload and short-circuit proof\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNode Type:\u003c\/strong\u003e A\/B node with extended addressing capability for up to 62 nodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing:\u003c\/strong\u003e One-piece design with stainless steel base for durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Tool-free installation with metal threaded inserts featuring SPEEDCON technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlat Cable Connection:\u003c\/strong\u003e Cable piercing technique with variable flat cable guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFAULT LED (Red):\u003c\/strong\u003e Indicates communication errors or address issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR LED (Green):\u003c\/strong\u003e AS-Interface voltage status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAUX LED (Green\/Red):\u003c\/strong\u003e External auxiliary voltage status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIN LEDs (Yellow):\u003c\/strong\u003e Input switching states\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOUT LEDs (Yellow\/Red):\u003c\/strong\u003e Output switching states and overload indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Monitoring:\u003c\/strong\u003e Configurable to ensure system integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP67, ensuring resistance to dust and water ingress\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -25°C to +70°C (-13°F to +158°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail mounting for easy integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAS-Interface Specification:\u003c\/strong\u003e V3.0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRequired Gateway Specification:\u003c\/strong\u003e ≥ V3.0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProfile:\u003c\/strong\u003e S-7.A.7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIO Code:\u003c\/strong\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eID Code:\u003c\/strong\u003e A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eID1 Code:\u003c\/strong\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eID2 Code:\u003c\/strong\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUL File Number:\u003c\/strong\u003e E223772\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuxiliary Voltage (UAUX):\u003c\/strong\u003e 24 V DC ± 15% PELV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e 26.5 to 31.6 V from AS-Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Operating Current (Ie):\u003c\/strong\u003e ≤ 40 mA (without sensors) \/ max. 240 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Class:\u003c\/strong\u003e III\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 21 to 31 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current Loading Capacity:\u003c\/strong\u003e ≤ 200 mA, overload and short-circuit protected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e ≤ 8 mA (limited internally)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching Point (According to DIN EN 61131-2, Type 2):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e0 (unattenuated): ≤ 2 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 (attenuated): ≥ 6 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Delay:\u003c\/strong\u003e \u0026lt; 1 ms (input\/AS-Interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e ≥ (UAUX - 0.5 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 2 A per output; 6 A total (TB ≤ 40°C); 4 A total (TB ≤ 70°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e PBT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeight:\u003c\/strong\u003e 35 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidth:\u003c\/strong\u003e 57.4 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e 151.6 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Mounting plate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Seamless integration of sensors and actuators into AS-Interface networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing:\u003c\/strong\u003e Reliable control of machinery and processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Coordination of conveyors and automated systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Synchronization of packaging equipment and sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose Pepperl+Fuchs VBA-4E4A-G12-ZAJ\/EA2L?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Addressing:\u003c\/strong\u003e Supports up to 62 nodes, enhancing network flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Stainless steel base and IP67 rating ensure longevity in harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Tool-free setup with SPEEDCON technology simplifies deployment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Indicators:\u003c\/strong\u003e LEDs provide clear status information for efficient diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e Overload and short-circuit protection for both inputs and outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882159288547,"sku":"VBA-4E4A-G12-ZAJ\/EA2L","price":756.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/VBA-4E4A-G12-ZAJ_EA2L.webp?v=1777373064","url":"https:\/\/flateck.myshopify.com\/pt\/products\/pepperl-fuchs-vba-4e4a-g12-zaj-ea2l-as-interface-module-4-pnp-inputs","provider":"Flateck Automation","version":"1.0","type":"link"}