{"product_id":"pepperl-fuchs-vaa-4e4a-ke-zejq-e2l-as-interface-module-4-inputs-amp-4-outputs","title":"Pepperl+Fuchs VAA-4E4A-KE-ZEJQ\/E2L","description":"\u003cp\u003eThe \u003cstrong\u003ePepperl+Fuchs VAA-4E4A-KE-ZEJQ\/E2L\u003c\/strong\u003e is a compact \u003cstrong\u003eAS-Interface sensor\/actuator module\u003c\/strong\u003e designed to facilitate seamless integration of sensors and actuators into AS-Interface networks. Featuring \u003cstrong\u003e4 inputs\u003c\/strong\u003e for 2- or 3-wire sensors and \u003cstrong\u003e4 electronic outputs\u003c\/strong\u003e, this module ensures reliable performance in industrial automation applications. Its slim \u003cstrong\u003e22.5 mm housing\u003c\/strong\u003e allows for space-saving DIN rail mounting in control cabinets.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e 4 channels compatible with 2- and 3-wire sensors (PNP), supporting both internal (from AS-Interface) and external power supply options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e 4 electronic PNP outputs, each capable of handling up to 2 A, with overload and short-circuit protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemovable Terminals:\u003c\/strong\u003e Mechanically and color-coded terminals for straightforward and error-free wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Monitoring:\u003c\/strong\u003e Integrated watchdog function deactivates outputs if communication is lost for more than 40 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFAULT LED (Red):\u003c\/strong\u003e Signals communication errors or output issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eINT LED (Green):\u003c\/strong\u003e Indicates active internal sensor supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR LED (Green):\u003c\/strong\u003e Displays AS-Interface voltage status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAUX LED (Green\/Red):\u003c\/strong\u003e Shows external auxiliary voltage status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIN LEDs (Yellow):\u003c\/strong\u003e Reflect input switching states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOUT LEDs (Yellow\/Red):\u003c\/strong\u003e Display output states and signal overload or lead breakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLead Breakage Detection:\u003c\/strong\u003e Switchable feature for detecting and reporting missing loads on outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Easy installation on standard 35 mm DIN rails, optimizing control cabinet space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e VAA-4E4A-KE-ZEJQ\/E2L\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAS-Interface Specification:\u003c\/strong\u003e V3.0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProfile:\u003c\/strong\u003e S-7.0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIO Code:\u003c\/strong\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eID Code:\u003c\/strong\u003e 0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eID1 Code:\u003c\/strong\u003e F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eID2 Code:\u003c\/strong\u003e E\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuxiliary Voltage (Input):\u003c\/strong\u003e 12 to 30 V DC (PELV)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuxiliary Voltage (Output):\u003c\/strong\u003e 20 to 30 V DC (PELV)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 26.5 to 31.6 V from AS-Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Operating Current:\u003c\/strong\u003e ≤ 35 mA (without sensors); max. 190 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Class:\u003c\/strong\u003e III\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e Overvoltage category III, safe isolated power supplies (PELV)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 21 to 31 V DC (internal supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current Loading Capacity:\u003c\/strong\u003e ≤ 150 mA, overload and short-circuit protected (internal supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e Up to 2 A per output, total up to 4 A (depending on ambient temperature and installation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -25°C to +60°C (-13°F to +140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e PA 66-FR\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Width 22.5 mm, Height 99 mm, Depth 102 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (EN 50022)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUL File Number:\u003c\/strong\u003e E223772\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCE Marked:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ecULus Listed:\u003c\/strong\u003e General Purpose\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Integrates sensors and actuators in conveyor systems for efficient sorting and routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Controls various sensors and actuators to ensure precise packaging operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomated Assembly Lines:\u003c\/strong\u003e Facilitates communication between control systems and field devices for synchronized assembly processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Monitors and controls field devices in industries such as chemical processing, pharmaceuticals, and food \u0026amp; beverage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose Pepperl+Fuchs VAA-4E4A-KE-ZEJQ\/E2L?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Slim 22.5 mm width conserves valuable control cabinet space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Input\/Output Configuration:\u003c\/strong\u003e Supports both 2- and 3-wire sensors with flexible power supply options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e Comprehensive LED indicators provide real-time status monitoring for quick troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust and Reliable:\u003c\/strong\u003e Built-in protections against overload, short-circuit, and communication loss ensure dependable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Removable, color-coded terminals and DIN rail mounting simplify setup and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882158141667,"sku":"VAA-4E4A-KE-ZEJQ\/E2L","price":1111.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/VAA-4E4A-KE-ZEJQ_E2L.webp?v=1777373051","url":"https:\/\/flateck.myshopify.com\/pt\/products\/pepperl-fuchs-vaa-4e4a-ke-zejq-e2l-as-interface-module-4-inputs-amp-4-outputs","provider":"Flateck Automation","version":"1.0","type":"link"}