{"product_id":"pepperl-fuchs-kfd2-ufc-ex1-d-frequency-converter-sil-2-0-4-20-ma-output","title":"Pepperl+Fuchs KFD2-UFC-Ex1.D","description":"\u003cp\u003eThe \u003cstrong\u003eKFD2-UFC-Ex1.D\u003c\/strong\u003e from \u003cstrong\u003ePepperl+Fuchs\u003c\/strong\u003e is a \u003cstrong\u003euniversal frequency converter and trip amplifier\u003c\/strong\u003e used to safely interface signals from hazardous areas. It converts digital pulse signals from NAMUR sensors or mechanical contacts into proportional \u003cstrong\u003eanalog current outputs\u003c\/strong\u003e (0\/4–20 mA) and provides \u003cstrong\u003etwo relay outputs\u003c\/strong\u003e for alarm\/trip functions. It is ideal for applications requiring \u003cstrong\u003efrequency-to-current conversion\u003c\/strong\u003e, \u003cstrong\u003espeed monitoring\u003c\/strong\u003e, and \u003cstrong\u003eflow signal conditioning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis unit is certified for \u003cstrong\u003eSIL 2 functional safety\u003c\/strong\u003e per IEC 61508\/61511 and designed for \u003cstrong\u003eDIN rail mounting\u003c\/strong\u003e in process control panels.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Input:\u003c\/strong\u003e NAMUR sensor or dry contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 0.001 Hz to 5,000 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e Configurable 0–20 mA or 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSwitch Outputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e2 × Relay contacts (trip alarms)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Transistor output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC via Power Rail or terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 100 ms for analog output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL Rating:\u003c\/strong\u003e SIL 2 (SC3) according to IEC\/EN 61508\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Fault Detection (LFD):\u003c\/strong\u003e Open\/short-circuit detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e KFD2-UFC-Ex1.D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Part Number:\u003c\/strong\u003e 231194\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e NAMUR sensor or mechanical contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog: 0\/4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay: 250 V AC \/ 2 A, 40 V DC \/ 2 A (resistive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransistor: Passive open collector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e Approx. 2.2 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -20 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 40 mm (W) × 119 mm (H) × 115 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 180 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFlow measurement systems (frequency-to-current conversion)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotational speed monitoring with trip alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulse monitoring in process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous area signal conversion with safety compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose the KFD2-UFC-Ex1.D?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eConverts frequency signals to standard analog output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in safety with SIL 2 compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay outputs for alarm or control logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEasy installation via DIN rail and Power Rail compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882176983267,"sku":"KFD2-UFC-Ex1.D-231194","price":648.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/KFD2-UFC-Ex1.D.webp?v=1777373243","url":"https:\/\/flateck.myshopify.com\/pt\/products\/pepperl-fuchs-kfd2-ufc-ex1-d-frequency-converter-sil-2-0-4-20-ma-output","provider":"Flateck Automation","version":"1.0","type":"link"}