{"product_id":"pepperl-fuchs-kfd2-gut-ex1-d-1-channel-signal-isolator-intrinsically-safe-din-rail-part-no-231225","title":"Pepperl+Fuchs KFD2-GUT-EX1.D","description":"\u003cp\u003eThe \u003cstrong\u003ePepperl+Fuchs KFD2-GUT-EX1.D\u003c\/strong\u003e (Part No. \u003cstrong\u003e231225\u003c\/strong\u003e) is a \u003cstrong\u003e1-channel signal conditioner and isolator\u003c\/strong\u003e for \u003cstrong\u003eintrinsically safe circuits\u003c\/strong\u003e, designed to process analog signals from field devices located in hazardous areas. It ensures \u003cstrong\u003esafe and reliable transmission of 0\/4…20 mA signals\u003c\/strong\u003e across safe and hazardous zones in industrial process automation.\u003c\/p\u003e\n\u003cp\u003eMounted on a \u003cstrong\u003eDIN rail\u003c\/strong\u003e, this module provides \u003cstrong\u003egalvanic isolation\u003c\/strong\u003e, signal conversion, and high reliability for use in \u003cstrong\u003echemical plants, oil \u0026amp; gas, and pharmaceutical environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1 Channel Input\u003c\/strong\u003e – For analog 0\/4–20 mA signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntrinsically Safe\u003c\/strong\u003e – Certified for hazardous area applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e – Input\/output\/power isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact DIN Rail Mounting\u003c\/strong\u003e – Saves space in control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGreen LED Status Indicator\u003c\/strong\u003e – Visual power confirmation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Operating Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Screw terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-GUT-EX1.D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 231225\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Analog (0\/4–20 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (35 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 20–30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e Approx. 1.3 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e ≥ 1.5 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Width:\u003c\/strong\u003e 12.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Instrumentation\u003c\/strong\u003e – Safe transmission of analog signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Automation\u003c\/strong\u003e – Isolated input for control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas, Chemical, and Pharmaceutical\u003c\/strong\u003e – Safety-certified signal conditioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose the KFD2-GUT-EX1.D?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePepperl+Fuchs reliability\u003c\/strong\u003e for intrinsic safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for safe analog signal processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact and easy to install on DIN rail systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882171379939,"sku":"KFD2-GUT-EX1.D","price":907.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/Texto-do-seu-paragrafo_75cfb175-181c-4143-83e2-04fee1f58d3f.webp?v=1777373180","url":"https:\/\/flateck.myshopify.com\/pt\/products\/pepperl-fuchs-kfd2-gut-ex1-d-1-channel-signal-isolator-intrinsically-safe-din-rail-part-no-231225","provider":"Flateck Automation","version":"1.0","type":"link"}