{"product_id":"pepperl-fuchs-kfd2-br-1-pa-1500-segment-coupler-profibus-dp-to-pa-gateway","title":"Pepperl+Fuchs KFD2-BR-1.PA.1500","description":"\u003cp\u003eThe \u003cstrong\u003eKFD2-BR-1.PA.1500\u003c\/strong\u003e is a \u003cstrong\u003eFieldConnex® Segment Coupler\u003c\/strong\u003e from \u003cstrong\u003ePepperl+Fuchs\u003c\/strong\u003e, designed to seamlessly connect PROFIBUS PA field devices to a PROFIBUS DP control system. This all-in-one gateway and power supply provides a high-power trunk, supporting long cable lengths and a high device count. It ensures transparent communication between DP and PA networks, simplifying system design and reducing engineering efforts.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransparent Gateway:\u003c\/strong\u003e Connects PROFIBUS PA devices to PROFIBUS DP without configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Power Output:\u003c\/strong\u003e 24–26 V DC, up to 400 mA, suitable for long cable runs and multiple devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Terminator:\u003c\/strong\u003e Selectable PROFIBUS DP terminator for network stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR (Green):\u003c\/strong\u003e Power on\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDP\/ERR (Red):\u003c\/strong\u003e DP error or hardware fault\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePA (Red):\u003c\/strong\u003e PA communication status or overload\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Suitable for Zone 2 \/ Class I, Div. 2 hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail mountable with Power Rail support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing:\u003c\/strong\u003e Compact polycarbonate enclosure with IP20 protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 277830\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 20–30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e Max. 2.5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Current:\u003c\/strong\u003e 640 mA to 365 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFieldbus Connections:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePROFIBUS PA:\u003c\/strong\u003e Terminals 3+, 6+, 2-, 5-, 1 shield, 4 shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePROFIBUS DP:\u003c\/strong\u003e Terminals 7 RxD\/TxD-P, 8 RxD\/TxD-N, 9 shield, 10 FE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaud Rate:\u003c\/strong\u003e Up to 1.5 MBit\/s (auto-adapting)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDP\/PA:\u003c\/strong\u003e Functional insulation, 50 V AC \/ 70 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDP\/Supply \u0026amp; PA\/Supply:\u003c\/strong\u003e Basic insulation, 253 V AC \/ 357 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e -40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e \u0026lt;95%, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 15 g, 11 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 1 g, 10–150 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (W×H×D):\u003c\/strong\u003e 20 × 115 × 111.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 180 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eATEX:\u003c\/strong\u003e II 3G Ex ec IIC T4 Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIECEx:\u003c\/strong\u003e Ex ec IIC T4 Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e EN 61326-1:2013, NAMUR NE 21\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFieldbus Standard:\u003c\/strong\u003e EN 50170\/2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IEC\/EN 60529\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClimatic Conditions:\u003c\/strong\u003e DIN IEC 721\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock\/Vibration:\u003c\/strong\u003e EN 60068-2-27 \/ EN 60068-2-6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Automation Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical and Petrochemical Industries\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil and Gas Facilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical Manufacturing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater and Wastewater Treatment Plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose Pepperl+Fuchs KFD2-BR-1.PA.1500?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Integration:\u003c\/strong\u003e Transparent communication between PROFIBUS DP and PA reduces configuration efforts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Design:\u003c\/strong\u003e Suitable for hazardous areas with high shock and vibration resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Saves space in control cabinets with DIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e Ensures stable operation with integrated terminators and diagnostic LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Certifications:\u003c\/strong\u003e Meets international standards for safety and performance \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882138120419,"sku":"KFD2-BR-1.PA.1500","price":3403.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/KFD2-BR-1.PA.1500.webp?v=1777372841","url":"https:\/\/flateck.myshopify.com\/pt\/products\/pepperl-fuchs-kfd2-br-1-pa-1500-segment-coupler-profibus-dp-to-pa-gateway","provider":"Flateck Automation","version":"1.0","type":"link"}