{"product_id":"pepperl-fuchs-kcd2-stc-ex1-2o-1-channel-smart-transmitter-power-supply","title":"Pepperl+Fuchs KCD2-STC-Ex1.2O","description":"\u003cp\u003eThe \u003cstrong\u003eKCD2-STC-Ex1.2O\u003c\/strong\u003e is a \u003cstrong\u003e1-channel isolated barrier\u003c\/strong\u003e from \u003cstrong\u003ePepperl+Fuchs\u003c\/strong\u003e, designed to supply power to \u003cstrong\u003e2-wire SMART transmitters\u003c\/strong\u003e in hazardous areas. It provides \u003cstrong\u003edual analog outputs\u003c\/strong\u003e (current or voltage) and supports \u003cstrong\u003ebi-directional communication\u003c\/strong\u003e for protocols like HART and BRAIN. The device is \u003cstrong\u003eSIL 2 certified\u003c\/strong\u003e according to IEC\/EN 61508, ensuring high reliability in safety-critical applications.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Analog input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 0\/4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Output:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent:\u003c\/strong\u003e 0\/4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 0\/1–5 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 19–30 V DC via Power Rail or terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Galvanic isolation between input, output, and power supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e Supports HART and BRAIN protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e DIP switches for selecting output mode (source\/sink\/voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators:\u003c\/strong\u003e LED for power supply status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e 35 mm DIN rail (EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Dimensions (W×H×D):\u003c\/strong\u003e 12.5 × 124 × 114 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 100 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 272955\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Terminals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSink Mode:\u003c\/strong\u003e Terminals 1+, 2-\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSource Mode:\u003c\/strong\u003e Terminals 3+, 4-\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Terminals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSource Mode:\u003c\/strong\u003e Terminals 5-, 6+; 7-, 8+\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSink Mode:\u003c\/strong\u003e Terminals 5+, 6-; 7+, 8-\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Resistance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Output:\u003c\/strong\u003e 0–500 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Output:\u003c\/strong\u003e \u0026gt;1 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Drop (Input):\u003c\/strong\u003e ≤6.1 V at 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShort-Circuit Current (Input):\u003c\/strong\u003e 25 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminals 1+, 2-:\u003c\/strong\u003e Max. 500 Ω (BRAIN)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminals 3+, 4-:\u003c\/strong\u003e ≤310 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Voltage (Input):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e≥16 V at 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e≥18.5 V at 4 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRipple (Output):\u003c\/strong\u003e Max. 50 µA rms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransfer Accuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Output:\u003c\/strong\u003e \u0026lt;20 µA (0.1%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Output:\u003c\/strong\u003e \u0026lt;10 mV (0.2%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Influence:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Output:\u003c\/strong\u003e 0.25 µA\/K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Output:\u003c\/strong\u003e 80 µV\/K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField to Control Side:\u003c\/strong\u003e 0–6 kHz (-3 dB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl to Field Side:\u003c\/strong\u003e 0.3–6 kHz (-3 dB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSettling Time:\u003c\/strong\u003e 6 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRise\/Fall Time:\u003c\/strong\u003e 2 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity Level (SIL):\u003c\/strong\u003e SIL 2 (SC 3) per IEC\/EN 61508\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e -20 °C to +60 °C (extended up to +70 °C with specific mounting conditions)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eATEX:\u003c\/strong\u003e II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIECEx:\u003c\/strong\u003e [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUL:\u003c\/strong\u003e cULus Listed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCE:\u003c\/strong\u003e EN 61326-1:2013 (industrial locations)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUKCA:\u003c\/strong\u003e CML 21UKEX2894X\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical and Petrochemical Industries\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil and Gas Exploration and Processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical Manufacturing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater and Wastewater Treatment Plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFood and Beverage Processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation Facilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose Pepperl+Fuchs KCD2-STC-Ex1.2O?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Output Capability:\u003c\/strong\u003e Provides both current and voltage outputs for versatile integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntrinsic Safety:\u003c\/strong\u003e Ensures safe operation in hazardous areas with intrinsic safety certifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 2 Certified:\u003c\/strong\u003e Meets stringent safety requirements for critical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Slim 12.5 mm housing saves space in control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Configuration:\u003c\/strong\u003e DIP switches allow for straightforward setup and mode selection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Compatibility:\u003c\/strong\u003e Facilitates advanced diagnostics and communication with HART-enabled devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e High accuracy and low ripple ensure precise signal transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882138349795,"sku":"KCD2-STC-Ex1.2O","price":475.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/KCD2-STC-Ex1.2O.webp?v=1777372843","url":"https:\/\/flateck.myshopify.com\/pt\/products\/pepperl-fuchs-kcd2-stc-ex1-2o-1-channel-smart-transmitter-power-supply","provider":"Flateck Automation","version":"1.0","type":"link"}