{"product_id":"lenze-e82zafsc001-function-module-safe-torque-off-for-8200-series","title":"Lenze E82ZAFSC001","description":"\u003cp class=\"\" data-end=\"424\" data-start=\"192\"\u003eThe \u003cstrong data-end=\"217\" data-start=\"196\"\u003eLenze E82ZAFSC001\u003c\/strong\u003e is a safety function module designed for use with Lenze 8200 series frequency inverters. It enables \u003cstrong data-end=\"343\" data-start=\"318\"\u003eSafe Torque Off (STO)\u003c\/strong\u003e functionality, enhancing system safety by preventing unintended motor operation.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"446\" data-start=\"426\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul data-end=\"694\" data-start=\"448\"\u003e\n\u003cli class=\"\" data-end=\"487\" data-start=\"448\"\u003e\n\u003cp class=\"\" data-end=\"487\" data-start=\"450\"\u003e\u003cstrong data-end=\"463\" data-start=\"450\"\u003eFunction:\u003c\/strong\u003e Safe Torque Off (STO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"535\" data-start=\"488\"\u003e\n\u003cp class=\"\" data-end=\"535\" data-start=\"490\"\u003e\u003cstrong data-end=\"508\" data-start=\"490\"\u003eCompatibility:\u003c\/strong\u003e Lenze 8200 series drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"584\" data-start=\"536\"\u003e\n\u003cp class=\"\" data-end=\"584\" data-start=\"538\"\u003e\u003cstrong data-end=\"558\" data-start=\"538\"\u003eSafety Category:\u003c\/strong\u003e SIL 2, PL d, Category 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"622\" data-start=\"585\"\u003e\n\u003cp class=\"\" data-end=\"622\" data-start=\"587\"\u003e\u003cstrong data-end=\"605\" data-start=\"587\"\u003eMounting Type:\u003c\/strong\u003e Plug-in module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"652\" data-start=\"623\"\u003e\n\u003cp class=\"\" data-end=\"652\" data-start=\"625\"\u003e\u003cstrong data-end=\"643\" data-start=\"625\"\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 1 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"694\" data-start=\"653\"\u003e\n\u003cp class=\"\" data-end=\"694\" data-start=\"655\"\u003e\u003cstrong data-end=\"671\" data-start=\"655\"\u003eDiagnostics:\u003c\/strong\u003e Integrated status LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"728\" data-start=\"696\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul data-end=\"996\" data-start=\"730\"\u003e\n\u003cli class=\"\" data-end=\"778\" data-start=\"730\"\u003e\n\u003cp class=\"\" data-end=\"778\" data-start=\"732\"\u003e\u003cstrong data-end=\"746\" data-start=\"732\"\u003eStandards:\u003c\/strong\u003e IEC 61800-5-2, EN ISO 13849-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"820\" data-start=\"779\"\u003e\n\u003cp class=\"\" data-end=\"820\" data-start=\"781\"\u003e\u003cstrong data-end=\"803\" data-start=\"781\"\u003eTemperature Range:\u003c\/strong\u003e -10°C to +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"857\" data-start=\"821\"\u003e\n\u003cp class=\"\" data-end=\"857\" data-start=\"823\"\u003e\u003cstrong data-end=\"840\" data-start=\"823\"\u003eStorage Temp:\u003c\/strong\u003e -25°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"919\" data-start=\"858\"\u003e\n\u003cp class=\"\" data-end=\"919\" data-start=\"860\"\u003e\u003cstrong data-end=\"887\" data-start=\"860\"\u003eDimensions (H x W x D):\u003c\/strong\u003e Approx. 45 mm x 22 mm x 65 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"948\" data-start=\"920\"\u003e\n\u003cp class=\"\" data-end=\"948\" data-start=\"922\"\u003e\u003cstrong data-end=\"933\" data-start=\"922\"\u003eWeight:\u003c\/strong\u003e Approx. 50 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"996\" data-start=\"949\"\u003e\n\u003cp class=\"\" data-end=\"996\" data-start=\"951\"\u003e\u003cstrong data-end=\"970\" data-start=\"951\"\u003eCertifications:\u003c\/strong\u003e CE, UL, cUL, TÜV approved\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1018\" data-start=\"998\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul data-end=\"1170\" data-start=\"1020\"\u003e\n\u003cli class=\"\" data-end=\"1047\" data-start=\"1020\"\u003e\n\u003cp class=\"\" data-end=\"1047\" data-start=\"1022\"\u003eSafety-critical systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1078\" data-start=\"1048\"\u003e\n\u003cp class=\"\" data-end=\"1078\" data-start=\"1050\"\u003eEmergency stop integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1104\" data-start=\"1079\"\u003e\n\u003cp class=\"\" data-end=\"1104\" data-start=\"1081\"\u003eIndustrial automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1136\" data-start=\"1105\"\u003e\n\u003cp class=\"\" data-end=\"1136\" data-start=\"1107\"\u003eMachine tools and conveyors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1170\" data-start=\"1137\"\u003e\n\u003cp class=\"\" data-end=\"1170\" data-start=\"1139\"\u003ePackaging and process machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1199\" data-start=\"1172\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eProduct Description:\u003c\/h3\u003e\n\u003cp class=\"\" data-end=\"1395\" data-start=\"1201\"\u003eThe \u003cstrong data-end=\"1226\" data-start=\"1205\"\u003eLenze E82ZAFSC001\u003c\/strong\u003e STO function module enhances machine safety by reliably disabling torque without disconnecting power. Ideal for applications requiring compliance with safety standards.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"1434\" data-start=\"1397\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose Lenze E82ZAFSC001?:\u003c\/h3\u003e\n\u003cul data-end=\"1612\" data-start=\"1436\"\u003e\n\u003cli class=\"\" data-end=\"1474\" data-start=\"1436\"\u003e\n\u003cp class=\"\" data-end=\"1474\" data-start=\"1438\"\u003eCertified safety for peace of mind\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1528\" data-start=\"1475\"\u003e\n\u003cp class=\"\" data-end=\"1528\" data-start=\"1477\"\u003eEasy integration into existing 8200 drive systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1566\" data-start=\"1529\"\u003e\n\u003cp class=\"\" data-end=\"1566\" data-start=\"1531\"\u003eQuick response and compact design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1612\" data-start=\"1567\"\u003e\n\u003cp class=\"\" data-end=\"1612\" data-start=\"1569\"\u003eHelps meet international safety regulations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48881757815011,"sku":"E82ZAFSC001","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/E82ZAFSC001.webp?v=1777369309","url":"https:\/\/flateck.myshopify.com\/pt\/products\/lenze-e82zafsc001-function-module-safe-torque-off-for-8200-series","provider":"Flateck Automation","version":"1.0","type":"link"}