{"product_id":"beckhoff-el4124-analog-output-terminal","title":"Beckhoff EL4124","description":"\u003cp data-end=\"709\" data-start=\"413\"\u003eThe \u003cstrong data-end=\"436\" data-start=\"417\"\u003eBeckhoff EL4124\u003c\/strong\u003e is a \u003cstrong data-end=\"478\" data-start=\"442\"\u003e4-channel analog output terminal\u003c\/strong\u003e designed for generating output signals in the range of ±10 V with 12-bit resolution. It provides precise analog signal generation, making it ideal for controlling actuators, setpoints, and other devices in industrial automation.\u003c\/p\u003e\n\u003ch3 data-end=\"733\" data-start=\"711\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"731\" data-start=\"715\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"969\" data-start=\"734\"\u003e\n\u003cli data-end=\"762\" data-start=\"734\"\u003e\n\u003cp data-end=\"762\" data-start=\"736\"\u003e4 analog output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"786\" data-start=\"763\"\u003e\n\u003cp data-end=\"786\" data-start=\"765\"\u003eOutput range: ±10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"836\" data-start=\"787\"\u003e\n\u003cp data-end=\"836\" data-start=\"789\"\u003e12-bit resolution for accurate signal control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"890\" data-start=\"837\"\u003e\n\u003cp data-end=\"890\" data-start=\"839\"\u003eElectrical isolation between field and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"932\" data-start=\"891\"\u003e\n\u003cp data-end=\"932\" data-start=\"893\"\u003eDiagnostic LEDs for status monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"969\" data-start=\"933\"\u003e\n\u003cp data-end=\"969\" data-start=\"935\"\u003eCompact DIN-rail terminal design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1005\" data-start=\"971\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1003\" data-start=\"975\"\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1393\" data-start=\"1006\"\u003e\n\u003cli data-end=\"1035\" data-start=\"1006\"\u003e\n\u003cp data-end=\"1035\" data-start=\"1008\"\u003e\u003cstrong data-end=\"1026\" data-start=\"1008\"\u003eBeckhoff Code:\u003c\/strong\u003e EL4124\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1072\" data-start=\"1036\"\u003e\n\u003cp data-end=\"1072\" data-start=\"1038\"\u003e\u003cstrong data-end=\"1047\" data-start=\"1038\"\u003eType:\u003c\/strong\u003e Analog Output Terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1092\" data-start=\"1073\"\u003e\n\u003cp data-end=\"1092\" data-start=\"1075\"\u003e\u003cstrong data-end=\"1088\" data-start=\"1075\"\u003eChannels:\u003c\/strong\u003e 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1128\" data-start=\"1093\"\u003e\n\u003cp data-end=\"1128\" data-start=\"1095\"\u003e\u003cstrong data-end=\"1120\" data-start=\"1095\"\u003eOutput Voltage Range:\u003c\/strong\u003e ±10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1155\" data-start=\"1129\"\u003e\n\u003cp data-end=\"1155\" data-start=\"1131\"\u003e\u003cstrong data-end=\"1146\" data-start=\"1131\"\u003eResolution:\u003c\/strong\u003e 12-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1203\" data-start=\"1156\"\u003e\n\u003cp data-end=\"1203\" data-start=\"1158\"\u003e\u003cstrong data-end=\"1189\" data-start=\"1158\"\u003eOutput Current per Channel:\u003c\/strong\u003e up to 10 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1255\" data-start=\"1204\"\u003e\n\u003cp data-end=\"1255\" data-start=\"1206\"\u003e\u003cstrong data-end=\"1241\" data-start=\"1206\"\u003eCurrent Consumption (from bus):\u003c\/strong\u003e typ. 180 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1289\" data-start=\"1256\"\u003e\n\u003cp data-end=\"1289\" data-start=\"1258\"\u003e\u003cstrong data-end=\"1283\" data-start=\"1258\"\u003eElectrical Isolation:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1335\" data-start=\"1290\"\u003e\n\u003cp data-end=\"1335\" data-start=\"1292\"\u003e\u003cstrong data-end=\"1318\" data-start=\"1292\"\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1362\" data-start=\"1336\"\u003e\n\u003cp data-end=\"1362\" data-start=\"1338\"\u003e\u003cstrong data-end=\"1351\" data-start=\"1338\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1393\" data-start=\"1363\"\u003e\n\u003cp data-end=\"1393\" data-start=\"1365\"\u003e\u003cstrong data-end=\"1384\" data-start=\"1365\"\u003eCertifications:\u003c\/strong\u003e CE, UL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1417\" data-start=\"1395\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1415\" data-start=\"1399\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1604\" data-start=\"1418\"\u003e\n\u003cli data-end=\"1453\" data-start=\"1418\"\u003e\n\u003cp data-end=\"1453\" data-start=\"1420\"\u003eControl of actuators and drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1497\" data-start=\"1454\"\u003e\n\u003cp data-end=\"1497\" data-start=\"1456\"\u003eSetpoint generation for process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1536\" data-start=\"1498\"\u003e\n\u003cp data-end=\"1536\" data-start=\"1500\"\u003eAutomation and measurement systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1567\" data-start=\"1537\"\u003e\n\u003cp data-end=\"1567\" data-start=\"1539\"\u003eIndustrial machine control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1604\" data-start=\"1568\"\u003e\n\u003cp data-end=\"1604\" data-start=\"1570\"\u003eModular Beckhoff I\/O integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1643\" data-start=\"1606\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1641\" data-start=\"1610\"\u003eWhy Choose Beckhoff EL4124?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1834\" data-start=\"1644\"\u003e\n\u003cli data-end=\"1684\" data-start=\"1644\"\u003e\n\u003cp data-end=\"1684\" data-start=\"1646\"\u003e4 independent analog output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1725\" data-start=\"1685\"\u003e\n\u003cp data-end=\"1725\" data-start=\"1687\"\u003eHigh accuracy with 12-bit resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1776\" data-start=\"1726\"\u003e\n\u003cp data-end=\"1776\" data-start=\"1728\"\u003eReliable signal control in industrial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1834\" data-start=\"1777\"\u003e\n\u003cp data-end=\"1834\" data-start=\"1779\"\u003eSeamless integration with Beckhoff EtherCAT terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48872044462307,"sku":"EL4124","price":409.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/EL4124.webp?v=1777120958","url":"https:\/\/flateck.myshopify.com\/pt\/products\/beckhoff-el4124-analog-output-terminal","provider":"Flateck Automation","version":"1.0","type":"link"}