{"product_id":"beckhoff-el3112-analog-input-terminal","title":"Beckhoff EL3112","description":"\u003cp data-end=\"720\" data-start=\"410\"\u003eThe \u003cstrong data-end=\"433\" data-start=\"414\"\u003eBeckhoff EL3112\u003c\/strong\u003e is a \u003cstrong data-end=\"474\" data-start=\"439\"\u003e2-channel analog input terminal\u003c\/strong\u003e designed to measure voltage signals in the range of ±10 V with \u003cstrong data-end=\"559\" data-start=\"538\"\u003e12-bit resolution\u003c\/strong\u003e. It ensures high-precision data acquisition, making it ideal for monitoring sensors, transducers, and process variables in industrial automation environments.\u003c\/p\u003e\n\u003ch3 data-end=\"744\" data-start=\"722\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"742\" data-start=\"726\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"984\" data-start=\"745\"\u003e\n\u003cli data-end=\"772\" data-start=\"745\"\u003e\n\u003cp data-end=\"772\" data-start=\"747\"\u003e2 analog input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"803\" data-start=\"773\"\u003e\n\u003cp data-end=\"803\" data-start=\"775\"\u003eInput voltage range: ±10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"850\" data-start=\"804\"\u003e\n\u003cp data-end=\"850\" data-start=\"806\"\u003e12-bit resolution for precise measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"904\" data-start=\"851\"\u003e\n\u003cp data-end=\"904\" data-start=\"853\"\u003eElectrical isolation between field and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"947\" data-start=\"905\"\u003e\n\u003cp data-end=\"947\" data-start=\"907\"\u003eDiagnostic LEDs for operational status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"984\" data-start=\"948\"\u003e\n\u003cp data-end=\"984\" data-start=\"950\"\u003eCompact DIN-rail terminal design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1020\" data-start=\"986\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1018\" data-start=\"990\"\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1417\" data-start=\"1021\"\u003e\n\u003cli data-end=\"1050\" data-start=\"1021\"\u003e\n\u003cp data-end=\"1050\" data-start=\"1023\"\u003e\u003cstrong data-end=\"1041\" data-start=\"1023\"\u003eBeckhoff Code:\u003c\/strong\u003e EL3112\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1086\" data-start=\"1051\"\u003e\n\u003cp data-end=\"1086\" data-start=\"1053\"\u003e\u003cstrong data-end=\"1062\" data-start=\"1053\"\u003eType:\u003c\/strong\u003e Analog Input Terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1106\" data-start=\"1087\"\u003e\n\u003cp data-end=\"1106\" data-start=\"1089\"\u003e\u003cstrong data-end=\"1102\" data-start=\"1089\"\u003eChannels:\u003c\/strong\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1141\" data-start=\"1107\"\u003e\n\u003cp data-end=\"1141\" data-start=\"1109\"\u003e\u003cstrong data-end=\"1133\" data-start=\"1109\"\u003eInput Voltage Range:\u003c\/strong\u003e ±10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1168\" data-start=\"1142\"\u003e\n\u003cp data-end=\"1168\" data-start=\"1144\"\u003e\u003cstrong data-end=\"1159\" data-start=\"1144\"\u003eResolution:\u003c\/strong\u003e 12-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1219\" data-start=\"1169\"\u003e\n\u003cp data-end=\"1219\" data-start=\"1171\"\u003e\u003cstrong data-end=\"1206\" data-start=\"1171\"\u003eCurrent Consumption (from bus):\u003c\/strong\u003e typ. 40 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1279\" data-start=\"1220\"\u003e\n\u003cp data-end=\"1279\" data-start=\"1222\"\u003e\u003cstrong data-end=\"1266\" data-start=\"1222\"\u003eCurrent Consumption (from field supply):\u003c\/strong\u003e typ. 15 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1313\" data-start=\"1280\"\u003e\n\u003cp data-end=\"1313\" data-start=\"1282\"\u003e\u003cstrong data-end=\"1307\" data-start=\"1282\"\u003eElectrical Isolation:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1359\" data-start=\"1314\"\u003e\n\u003cp data-end=\"1359\" data-start=\"1316\"\u003e\u003cstrong data-end=\"1342\" data-start=\"1316\"\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1386\" data-start=\"1360\"\u003e\n\u003cp data-end=\"1386\" data-start=\"1362\"\u003e\u003cstrong data-end=\"1375\" data-start=\"1362\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1417\" data-start=\"1387\"\u003e\n\u003cp data-end=\"1417\" data-start=\"1389\"\u003e\u003cstrong data-end=\"1408\" data-start=\"1389\"\u003eCertifications:\u003c\/strong\u003e CE, UL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1441\" data-start=\"1419\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1439\" data-start=\"1423\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1643\" data-start=\"1442\"\u003e\n\u003cli data-end=\"1483\" data-start=\"1442\"\u003e\n\u003cp data-end=\"1483\" data-start=\"1444\"\u003eMeasurement of analog voltage signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1521\" data-start=\"1484\"\u003e\n\u003cp data-end=\"1521\" data-start=\"1486\"\u003eProcess automation and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1556\" data-start=\"1522\"\u003e\n\u003cp data-end=\"1556\" data-start=\"1524\"\u003eMachine control and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1601\" data-start=\"1557\"\u003e\n\u003cp data-end=\"1601\" data-start=\"1559\"\u003eIntegration with sensors and transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1643\" data-start=\"1602\"\u003e\n\u003cp data-end=\"1643\" data-start=\"1604\"\u003eModular Beckhoff EtherCAT I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1682\" data-start=\"1645\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1680\" data-start=\"1649\"\u003eWhy Choose Beckhoff EL3112?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1878\" data-start=\"1683\"\u003e\n\u003cli data-end=\"1727\" data-start=\"1683\"\u003e\n\u003cp data-end=\"1727\" data-start=\"1685\"\u003eAccurate 2-channel analog input terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1769\" data-start=\"1728\"\u003e\n\u003cp data-end=\"1769\" data-start=\"1730\"\u003eHigh precision with 12-bit resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1822\" data-start=\"1770\"\u003e\n\u003cp data-end=\"1822\" data-start=\"1772\"\u003eReliable performance for industrial applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1878\" data-start=\"1823\"\u003e\n\u003cp data-end=\"1878\" data-start=\"1825\"\u003eCompact and easy to integrate into Beckhoff systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48872044331235,"sku":"EL3112","price":609.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/EL3112.webp?v=1777120949","url":"https:\/\/flateck.myshopify.com\/pt\/products\/beckhoff-el3112-analog-input-terminal","provider":"Flateck Automation","version":"1.0","type":"link"}