{"product_id":"allen-bradley-440r-dg2r2t-guardmaster-safety-relay","title":"Allen-Bradley 440R-DG2R2T","description":"\u003cdiv class=\"markdown markdown-main-panel stronger\" id=\"model-response-message-contentr_5d909fac951905b2\" dir=\"ltr\"\u003e\n\u003cp data-sourcepos=\"17:1-17:725\"\u003eThe Allen-Bradley 440R-DG2R2T Guardmaster Multifunction DG (Dual GuardLink) Safety Relay is a highly versatile and configurable safety relay designed for complex safety applications. \u003cspan class=\"citation-0 recitation citation-end-0\"\u003eThis relay achieves Performance Level e (PLe) according to EN ISO 13849-1 and Safety Integrity Level 3 (SIL 3) according to IEC 61508.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e1\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-1 recitation citation-end-1\"\u003eIt features two safety inputs that can accept GuardLink, OSSD (Output Signal Switching Device), and traditional N.C. (Normally Closed) signals.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e2\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-2 recitation citation-end-2\"\u003eIt also offers two N.O. (Normally Open) safety outputs, two SWS (Safe Work Stop) inputs, and two SWS outputs.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e3\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-3 recitation citation-end-3\"\u003eThe relay supports both instantaneous and time-delayed safety functions and operates on 24V DC power.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e4\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"19:1-19:17\"\u003e\u003cstrong\u003e◆Key Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"21:1-28:0\"\u003e\n\u003cli data-sourcepos=\"21:1-21:204\"\u003e\n\u003cstrong\u003eGuardmaster Multifunction DG (Dual GuardLink):\u003c\/strong\u003e Offers advanced safety functionality and integration with GuardLink safety systems. Dual GuardLink means it can handle two separate GuardLink chains.\u003c\/li\u003e\n\u003cli data-sourcepos=\"22:1-22:124\"\u003e\n\u003cspan class=\"citation-4 recitation\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-4 recitation\"\u003ePLe (EN ISO 13849-1) \/ SIL 3 (IEC 61508):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-4 recitation citation-end-4\"\u003e Meets high safety standards for critical safety applications.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e5\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"23:1-23:121\"\u003e\n\u003cspan class=\"citation-5 recitation\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-5 recitation\"\u003e2 Safety Inputs (GuardLink, OSSD, N.C.):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-5 recitation citation-end-5\"\u003e Provides flexible input options for various safety devices.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e6\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"24:1-24:126\"\u003e\n\u003cspan class=\"citation-6 recitation\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-6 recitation\"\u003e2 N.O. Safety Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-6 recitation citation-end-6\"\u003e Provides two normally open safety outputs for controlling safety-related circuits.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e7\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"25:1-25:119\"\u003e\n\u003cspan class=\"citation-7 recitation\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-7 recitation\"\u003e2 SWS Inputs \/ 2 SWS Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-7 recitation citation-end-7\"\u003e Offers Safe Work Stop functionality for controlled machine stopping.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e8\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"26:1-26:109\"\u003e\n\u003cstrong\u003eInstantaneous and Time Delay:\u003c\/strong\u003e \u003cspan class=\"citation-8 recitation citation-end-8\"\u003eSupports both immediate and time-delayed safety responses.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e9\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"27:1-28:0\"\u003e\n\u003cspan class=\"citation-9 recitation\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-9 recitation\"\u003e24V DC Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-9 recitation citation-end-9\"\u003e Operates on a standard industrial 24V DC supply.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e10\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"29:1-29:29\"\u003e\u003cstrong\u003e◆Technical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"31:1-46:0\"\u003e\n\u003cli data-sourcepos=\"31:1-31:44\"\u003eProduct Type: Multifunction Safety Relay\u003c\/li\u003e\n\u003cli data-sourcepos=\"32:1-32:31\"\u003eCatalog Number: 440R-DG2R2T\u003c\/li\u003e\n\u003cli data-sourcepos=\"33:1-33:43\"\u003eSeries: Guardmaster DG (Dual GuardLink)\u003c\/li\u003e\n\u003cli data-sourcepos=\"34:1-34:50\"\u003eSafety Performance Level: PLe (EN ISO 13849-1)\u003c\/li\u003e\n\u003cli data-sourcepos=\"35:1-35:45\"\u003eSafety Integrity Level: SIL 3 (IEC 61508)\u003c\/li\u003e\n\u003cli data-sourcepos=\"36:1-36:44\"\u003eSafety Inputs: 2 (GuardLink, OSSD, N.C.)\u003c\/li\u003e\n\u003cli data-sourcepos=\"37:1-37:26\"\u003eSafety Outputs: 2 N.O.\u003c\/li\u003e\n\u003cli data-sourcepos=\"38:1-38:17\"\u003eSWS Inputs: 2\u003c\/li\u003e\n\u003cli data-sourcepos=\"39:1-39:18\"\u003eSWS Outputs: 2\u003c\/li\u003e\n\u003cli data-sourcepos=\"40:1-40:104\"\u003eTiming Functions: Instantaneous and Time Delay (Specify the range of time delays from documentation)\u003c\/li\u003e\n\u003cli data-sourcepos=\"41:1-41:24\"\u003ePower Supply: 24V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"47:1-47:17\"\u003e\u003cstrong\u003e◆Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"49:1-54:0\"\u003e\n\u003cli data-sourcepos=\"49:1-49:39\"\u003eComplex machine safety applications\u003c\/li\u003e\n\u003cli data-sourcepos=\"50:1-50:23\"\u003eSafety interlocking\u003c\/li\u003e\n\u003cli data-sourcepos=\"51:1-51:26\"\u003eEmergency stop systems\u003c\/li\u003e\n\u003cli data-sourcepos=\"52:1-52:20\"\u003eGuard monitoring\u003c\/li\u003e\n\u003cli data-sourcepos=\"53:1-54:0\"\u003eApplications requiring high levels of safety integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"55:1-55:33\"\u003e\u003cstrong\u003e◆Why Choose DD Parts Solution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"57:1-62:0\"\u003e\n\u003cli data-sourcepos=\"57:1-57:30\"\u003eFast and Reliable Shipping\u003c\/li\u003e\n\u003cli data-sourcepos=\"58:1-58:23\"\u003eCompetitive Pricing\u003c\/li\u003e\n\u003cli data-sourcepos=\"59:1-59:18\"\u003eExpert Support\u003c\/li\u003e\n\u003cli data-sourcepos=\"60:1-60:43\"\u003eWide Selection of Automation Components\u003c\/li\u003e\n\u003cli data-sourcepos=\"61:1-62:0\"\u003eTrusted Supplier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48840724807907,"sku":null,"price":718.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/440r-dg2r2t-1.webp?v=1776626618","url":"https:\/\/flateck.myshopify.com\/pt\/products\/allen-bradley-440r-dg2r2t-guardmaster-safety-relay","provider":"Flateck Automation","version":"1.0","type":"link"}