{"product_id":"abb-xt1n-160-miniature-circuit-breaker-mcb","title":"ABB XT1N 160 | 1SDA067416R1","description":"\u003ch2 class=\"\" data-end=\"181\" data-start=\"114\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"181\" data-start=\"117\"\u003eABB XT1N 160 | Molded Case Circuit Breaker 160A, 3-Pole, IEC\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp class=\"\" data-end=\"381\" data-start=\"183\"\u003e\u003cstrong data-end=\"211\" data-start=\"183\"\u003eGlobal Commercial Alias:\u003c\/strong\u003e XT1N 160\u003cstrong data-end=\"238\" data-start=\"223\"\u003eProduct ID:\u003c\/strong\u003e \u003cspan\u003e1SDA067416R1\u003c\/span\u003e\u003cstrong data-end=\"279\" data-start=\"254\"\u003eABB Type Designation:\u003c\/strong\u003e XT1N 160\u003cstrong data-end=\"315\" data-start=\"291\"\u003eCatalog Description:\u003c\/strong\u003e TMAX XT1 molded case circuit breaker, 160 A, 3-pole, IEC standard\u003c\/p\u003e\n\n\u003cp class=\"\" data-end=\"663\" data-start=\"397\"\u003eThe \u003cstrong data-end=\"476\" data-start=\"401\"\u003eABB XT1N 160 is a compact and robust molded case circuit breaker (MCCB)\u003c\/strong\u003e with a rated current of 160 A and 3-pole configuration. It ensures reliable circuit protection under demanding industrial and commercial conditions, complying with IEC 60947-2 standards.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"681\" data-start=\"665\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features\u003c\/h3\u003e\n\u003cul data-end=\"1222\" data-start=\"683\"\u003e\n\u003cli class=\"\" data-end=\"716\" data-start=\"683\"\u003e\n\u003cp class=\"\" data-end=\"716\" data-start=\"685\"\u003e\u003cstrong data-end=\"708\" data-start=\"685\"\u003eRated Current (In):\u003c\/strong\u003e 160 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"733\" data-start=\"717\"\u003e\n\u003cp class=\"\" data-end=\"733\" data-start=\"719\"\u003e\u003cstrong data-end=\"729\" data-start=\"719\"\u003ePoles:\u003c\/strong\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"778\" data-start=\"734\"\u003e\n\u003cp class=\"\" data-end=\"778\" data-start=\"736\"\u003e\u003cstrong data-end=\"770\" data-start=\"736\"\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e 800 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"831\" data-start=\"779\"\u003e\n\u003cp class=\"\" data-end=\"831\" data-start=\"781\"\u003e\u003cstrong data-end=\"814\" data-start=\"781\"\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e Up to 690 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"911\" data-start=\"832\"\u003e\n\u003cp class=\"\" data-end=\"911\" data-start=\"834\"\u003e\u003cstrong data-end=\"856\" data-start=\"834\"\u003eBreaking Capacity:\u003c\/strong\u003e Up to 36 kA at 415 V AC (dependent on model variant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"953\" data-start=\"912\"\u003e\n\u003cp class=\"\" data-end=\"953\" data-start=\"914\"\u003e\u003cstrong data-end=\"939\" data-start=\"914\"\u003eStandards Compliance:\u003c\/strong\u003e IEC 60947-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1028\" data-start=\"954\"\u003e\n\u003cp class=\"\" data-end=\"1028\" data-start=\"956\"\u003e\u003cstrong data-end=\"975\" data-start=\"956\"\u003eTrip Unit Type:\u003c\/strong\u003e Thermal-magnetic or electronic (varies by variant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1076\" data-start=\"1029\"\u003e\n\u003cp class=\"\" data-end=\"1076\" data-start=\"1031\"\u003e\u003cstrong data-end=\"1044\" data-start=\"1031\"\u003eMounting:\u003c\/strong\u003e Fixed or plug-in base options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1128\" data-start=\"1077\"\u003e\n\u003cp class=\"\" data-end=\"1128\" data-start=\"1079\"\u003e\u003cstrong data-end=\"1099\" data-start=\"1079\"\u003eConnection Type:\u003c\/strong\u003e Front terminal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1222\" data-start=\"1129\"\u003e\n\u003cp class=\"\" data-end=\"1222\" data-start=\"1131\"\u003e\u003cstrong data-end=\"1147\" data-start=\"1131\"\u003eAccessories:\u003c\/strong\u003e Compatible with auxiliary contacts, shunt trip, undervoltage release, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1252\" data-start=\"1224\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-end=\"1638\" data-start=\"1254\"\u003e\n\u003cli class=\"\" data-end=\"1284\" data-start=\"1254\"\u003e\n\u003cp class=\"\" data-end=\"1284\" data-start=\"1256\"\u003e\u003cstrong data-end=\"1273\" data-start=\"1256\"\u003eModel Number:\u003c\/strong\u003e XT1N 160\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1318\" data-start=\"1285\"\u003e\n\u003cp class=\"\" data-end=\"1318\" data-start=\"1287\"\u003e\u003cstrong data-end=\"1307\" data-start=\"1287\"\u003eRated Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1350\" data-start=\"1319\"\u003e\n\u003cp class=\"\" data-end=\"1350\" data-start=\"1321\"\u003e\u003cstrong data-end=\"1346\" data-start=\"1321\"\u003eUtilization Category:\u003c\/strong\u003e A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1399\" data-start=\"1351\"\u003e\n\u003cp class=\"\" data-end=\"1399\" data-start=\"1353\"\u003e\u003cstrong data-end=\"1373\" data-start=\"1353\"\u003eMechanical Life:\u003c\/strong\u003e Up to 20,000 operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1468\" data-start=\"1400\"\u003e\n\u003cp class=\"\" data-end=\"1468\" data-start=\"1402\"\u003e\u003cstrong data-end=\"1422\" data-start=\"1402\"\u003eElectrical Life:\u003c\/strong\u003e Up to 10,000 operations (dependent on load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1514\" data-start=\"1469\"\u003e\n\u003cp class=\"\" data-end=\"1514\" data-start=\"1471\"\u003e\u003cstrong data-end=\"1497\" data-start=\"1471\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1597\" data-start=\"1515\"\u003e\n\u003cp class=\"\" data-end=\"1597\" data-start=\"1517\"\u003e\u003cstrong data-end=\"1539\" data-start=\"1517\"\u003eProtection Degree:\u003c\/strong\u003e IP20 (without terminal covers), higher with accessories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1638\" data-start=\"1598\"\u003e\n\u003cp class=\"\" data-end=\"1638\" data-start=\"1600\"\u003e\u003cstrong data-end=\"1619\" data-start=\"1600\"\u003eCertifications:\u003c\/strong\u003e CE, EAC, UL, IEC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1656\" data-start=\"1640\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications\u003c\/h3\u003e\n\u003cul data-end=\"1840\" data-start=\"1658\"\u003e\n\u003cli class=\"\" data-end=\"1694\" data-start=\"1658\"\u003e\n\u003cp class=\"\" data-end=\"1694\" data-start=\"1660\"\u003eMain and sub-distribution panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1730\" data-start=\"1695\"\u003e\n\u003cp class=\"\" data-end=\"1730\" data-start=\"1697\"\u003eIndustrial plants and machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1774\" data-start=\"1731\"\u003e\n\u003cp class=\"\" data-end=\"1774\" data-start=\"1733\"\u003eCommercial buildings and infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1798\" data-start=\"1775\"\u003e\n\u003cp class=\"\" data-end=\"1798\" data-start=\"1777\"\u003eOEM control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1840\" data-start=\"1799\"\u003e\n\u003cp class=\"\" data-end=\"1840\" data-start=\"1801\"\u003eEnergy management and safety circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1865\" data-start=\"1842\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eProduct Description\u003c\/h3\u003e\n\u003cp class=\"\" data-end=\"2167\" data-start=\"1867\"\u003eThe \u003cstrong data-end=\"1883\" data-start=\"1871\"\u003eXT1N 160\u003c\/strong\u003e offers high-performance protection for electrical systems, featuring a modular design for easy installation and customization. With advanced breaking performance and reliable trip units, it meets a wide range of application needs, from basic protection to complex automation systems.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"2197\" data-start=\"2169\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose ABB XT1N 160?\u003c\/h3\u003e\n\u003cp class=\"\" data-end=\"2391\" data-start=\"2199\"\u003eHigh breaking capacity and reliabilityCompact design with flexible installationCompliant with international standardsWide range of accessories for enhanced functionality\u003c\/p\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48871980761315,"sku":"XT1N 160","price":592.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/XT1N-160.webp?v=1777118356","url":"https:\/\/flateck.myshopify.com\/pt\/products\/abb-xt1n-160-miniature-circuit-breaker-mcb","provider":"Flateck Automation","version":"1.0","type":"link"}