{"product_id":"6es7138-4fa05-0ab0-siemens-simatic-dp-electronics-module-f-et200s","title":"SIEMENS 6ES7138-4FA05-0AB0","description":"\u003cp data-end=\"910\" data-start=\"502\"\u003eThe \u003cstrong data-end=\"536\" data-start=\"506\"\u003eSiemens 6ES7138-4FA05-0AB0\u003c\/strong\u003e is a \u003cstrong data-end=\"576\" data-start=\"542\"\u003efail-safe digital input module\u003c\/strong\u003e for the \u003cstrong data-end=\"607\" data-start=\"585\"\u003eET 200S I\/O system\u003c\/strong\u003e, offering \u003cstrong data-end=\"655\" data-start=\"618\"\u003ehigh-performance safety functions\u003c\/strong\u003e in \u003cstrong data-end=\"697\" data-start=\"659\"\u003eindustrial automation environments\u003c\/strong\u003e. With \u003cstrong data-end=\"731\" data-start=\"704\"\u003ePROFIsafe communication\u003c\/strong\u003e, it ensures \u003cstrong data-end=\"787\" data-start=\"744\"\u003esecure and error-free data transmission\u003c\/strong\u003e, making it ideal for \u003cstrong data-end=\"840\" data-start=\"809\"\u003esafety-related applications\u003c\/strong\u003e in \u003cstrong data-end=\"907\" data-start=\"844\"\u003emachine automation, process control, and factory automation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-end=\"933\" data-start=\"912\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKEY FEATURES:\u003c\/h2\u003e\n\u003cul data-end=\"1418\" data-start=\"935\"\u003e\n\u003cli data-end=\"976\" data-start=\"935\"\u003e\n\u003cstrong data-end=\"947\" data-start=\"937\"\u003eModel:\u003c\/strong\u003e Siemens 6ES7138-4FA05-0AB0\u003c\/li\u003e\n\u003cli data-end=\"1008\" data-start=\"977\"\u003e\n\u003cstrong data-end=\"990\" data-start=\"979\"\u003eSeries:\u003c\/strong\u003e SIMATIC ET 200S\u003c\/li\u003e\n\u003cli data-end=\"1057\" data-start=\"1009\"\u003e\n\u003cstrong data-end=\"1020\" data-start=\"1011\"\u003eType:\u003c\/strong\u003e \u003cstrong data-end=\"1055\" data-start=\"1021\"\u003eFail-Safe Digital Input Module\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1132\" data-start=\"1058\"\u003e\n\u003cstrong data-end=\"1071\" data-start=\"1060\"\u003eInputs:\u003c\/strong\u003e \u003cstrong data-end=\"1130\" data-start=\"1072\"\u003e4 fail-safe digital inputs (24V DC, PROFIsafe-capable)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1192\" data-start=\"1133\"\u003e\n\u003cstrong data-end=\"1153\" data-start=\"1135\"\u003eCommunication:\u003c\/strong\u003e \u003cstrong data-end=\"1190\" data-start=\"1154\"\u003ePROFIsafe over PROFINET\/PROFIBUS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1274\" data-start=\"1193\"\u003e\n\u003cstrong data-end=\"1212\" data-start=\"1195\"\u003eSafety Level:\u003c\/strong\u003e \u003cstrong data-end=\"1272\" data-start=\"1213\"\u003eCompliant with SIL 3 (IEC 61508) and PL e (ISO 13849-1)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1351\" data-start=\"1275\"\u003e\n\u003cstrong data-end=\"1293\" data-start=\"1277\"\u003eDiagnostics:\u003c\/strong\u003e \u003cstrong data-end=\"1349\" data-start=\"1294\"\u003eComprehensive status and error diagnostics via LEDs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1418\" data-start=\"1352\"\u003e\n\u003cstrong data-end=\"1372\" data-start=\"1354\"\u003eCompatibility:\u003c\/strong\u003e \u003cstrong data-end=\"1416\" data-start=\"1373\"\u003eDesigned for ET 200S modular I\/O system\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1450\" data-start=\"1420\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTECHNICAL INFORMATION:\u003c\/h2\u003e\n\u003cul data-end=\"1909\" data-start=\"1452\"\u003e\n\u003cli data-end=\"1508\" data-start=\"1452\"\u003e\n\u003cstrong data-end=\"1475\" data-start=\"1454\"\u003eNumber of Inputs:\u003c\/strong\u003e \u003cstrong data-end=\"1506\" data-start=\"1476\"\u003e4 fail-safe digital inputs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1569\" data-start=\"1509\"\u003e\n\u003cstrong data-end=\"1529\" data-start=\"1511\"\u003eInput Voltage:\u003c\/strong\u003e \u003cstrong data-end=\"1567\" data-start=\"1530\"\u003e24V DC (according to IEC 61131-2)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1636\" data-start=\"1570\"\u003e\n\u003cstrong data-end=\"1592\" data-start=\"1572\"\u003eSafety Protocol:\u003c\/strong\u003e \u003cstrong data-end=\"1634\" data-start=\"1593\"\u003ePROFIsafe for fail-safe communication\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1707\" data-start=\"1637\"\u003e\n\u003cstrong data-end=\"1657\" data-start=\"1639\"\u003eResponse Time:\u003c\/strong\u003e \u003cstrong data-end=\"1705\" data-start=\"1658\"\u003eOptimized for fast safety signal processing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1767\" data-start=\"1708\"\u003e\n\u003cstrong data-end=\"1725\" data-start=\"1710\"\u003eConnection:\u003c\/strong\u003e \u003cstrong data-end=\"1765\" data-start=\"1726\"\u003ePush-in terminals for secure wiring\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1817\" data-start=\"1768\"\u003e\n\u003cstrong data-end=\"1796\" data-start=\"1770\"\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong data-end=\"1815\" data-start=\"1797\"\u003e-20°C to +60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1909\" data-start=\"1818\"\u003e\n\u003cstrong data-end=\"1839\" data-start=\"1820\"\u003eCertifications:\u003c\/strong\u003e \u003cstrong data-end=\"1907\" data-start=\"1840\"\u003eSIL 3 (IEC 61508), PL e (ISO 13849-1), CE, UL, cUL, ATEX Zone 2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1932\" data-start=\"1911\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eAPPLICATIONS:\u003c\/h2\u003e\n\u003cul data-end=\"2379\" data-start=\"1934\"\u003e\n\u003cli data-end=\"2027\" data-start=\"1934\"\u003e\n\u003cstrong data-end=\"1966\" data-start=\"1936\"\u003eIndustrial Safety Systems:\u003c\/strong\u003e \u003cstrong data-end=\"2025\" data-start=\"1967\"\u003eEnsures safe signal processing in manufacturing plants\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2114\" data-start=\"2028\"\u003e\n\u003cstrong data-end=\"2051\" data-start=\"2030\"\u003eMachine Guarding:\u003c\/strong\u003e \u003cstrong data-end=\"2112\" data-start=\"2052\"\u003eUsed in emergency stop circuits and interlocking systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2188\" data-start=\"2115\"\u003e\n\u003cstrong data-end=\"2140\" data-start=\"2117\"\u003eProcess Automation:\u003c\/strong\u003e \u003cstrong data-end=\"2186\" data-start=\"2141\"\u003eEnhances safety in hazardous environments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2283\" data-start=\"2189\"\u003e\n\u003cstrong data-end=\"2214\" data-start=\"2191\"\u003eFactory Automation:\u003c\/strong\u003e \u003cstrong data-end=\"2281\" data-start=\"2215\"\u003eIdeal for fail-safe integration in distributed control systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2379\" data-start=\"2284\"\u003e\n\u003cstrong data-end=\"2314\" data-start=\"2286\"\u003eCritical Infrastructure:\u003c\/strong\u003e \u003cstrong data-end=\"2377\" data-start=\"2315\"\u003eApplied in power plants, chemical processing, and robotics\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2398\" data-start=\"2381\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eBENEFITS:\u003c\/h2\u003e\n\u003cul data-end=\"2734\" data-start=\"2400\"\u003e\n\u003cli data-end=\"2472\" data-start=\"2400\"\u003e\u003cstrong data-end=\"2470\" data-start=\"2402\"\u003eFail-safe inputs ensure high reliability for safety applications\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2542\" data-start=\"2473\"\u003e\u003cstrong data-end=\"2540\" data-start=\"2475\"\u003ePROFIsafe communication minimizes risk of data loss or errors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2611\" data-start=\"2543\"\u003e\u003cstrong data-end=\"2609\" data-start=\"2545\"\u003eCompact design for seamless integration into ET 200S systems\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2668\" data-start=\"2612\"\u003e\u003cstrong data-end=\"2666\" data-start=\"2614\"\u003eMeets the highest safety standards (SIL 3, PL e)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2734\" data-start=\"2669\"\u003e\u003cstrong data-end=\"2732\" data-start=\"2671\"\u003eEasy installation and diagnostics reduce maintenance time\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2914\" data-start=\"2736\"\u003eThe \u003cstrong data-end=\"2770\" data-start=\"2740\"\u003eSiemens 6ES7138-4FA05-0AB0\u003c\/strong\u003e is a \u003cstrong data-end=\"2818\" data-start=\"2776\"\u003ehighly reliable fail-safe input module\u003c\/strong\u003e, ensuring \u003cstrong data-end=\"2869\" data-start=\"2829\"\u003esafe and efficient signal processing\u003c\/strong\u003e in \u003cstrong data-end=\"2911\" data-start=\"2873\"\u003eindustrial automation environments\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48885221359843,"sku":"6ES7138-4FA05-0AB0","price":304.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/6ES7138-4FA05-0AB0_4b516e34-58b1-4a7d-b392-71a529e99888.webp?v=1777401463","url":"https:\/\/flateck.myshopify.com\/pt\/products\/6es7138-4fa05-0ab0-siemens-simatic-dp-electronics-module-f-et200s","provider":"Flateck Automation","version":"1.0","type":"link"}