{"product_id":"x20so4110-b-r-digital-output-module-designed-for-industrial-automation-featuring-reliable-performance-compact-design-and-diagnostic-leds-for-efficient-control-and-monitoring","title":"B\u0026R X20SO4110","description":"\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R X20SO4110 | Safe Digital Output Module with 4 Channels, 0.5 A, and Current Monitoring\u003c\/strong\u003e\n\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eB\u0026amp;R X20SO4110\u003c\/strong\u003e is a \u003cstrong\u003esafe digital output module\u003c\/strong\u003e designed for industrial applications requiring high \u003cstrong\u003efunctional safety levels\u003c\/strong\u003e. Equipped with \u003cstrong\u003e4 safe digital outputs\u003c\/strong\u003e, each rated at \u003cstrong\u003e0.5 A\u003c\/strong\u003e, this module is suitable for controlling actuators in safety applications up to \u003cstrong\u003ePL e\u003c\/strong\u003e or \u003cstrong\u003eSIL 3\u003c\/strong\u003e. The outputs use semiconductor technology, ensuring that \u003cstrong\u003esafety characteristics remain independent of the number of operation cycles\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ehigh-side low-side\u003c\/strong\u003e variant (\u003cstrong\u003etype A output\u003c\/strong\u003e) is ideal for actuators without a reference potential, such as \u003cstrong\u003erelays and valves\u003c\/strong\u003e. Additionally, the module features \u003cstrong\u003eautomatic reset protection\u003c\/strong\u003e in case of network faults and \u003cstrong\u003ecurrent measurement for open circuit detection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour Safe Digital Outputs:\u003c\/strong\u003e Provides \u003cstrong\u003efour output channels\u003c\/strong\u003e, each rated at \u003cstrong\u003e0.5 A\u003c\/strong\u003e, for controlling actuators in \u003cstrong\u003esafety-critical applications\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Monitoring:\u003c\/strong\u003e Integrated \u003cstrong\u003ecurrent monitoring\u003c\/strong\u003e for each output allows \u003cstrong\u003eopen circuit detection\u003c\/strong\u003e, ensuring system integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Detection:\u003c\/strong\u003e Internal \u003cstrong\u003ecurrent measurement\u003c\/strong\u003e identifies open circuits, improving reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Output Protection:\u003c\/strong\u003e Built-in \u003cstrong\u003eoutput protection\u003c\/strong\u003e ensures safe operation under various conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified Functional Safety:\u003c\/strong\u003e Certified for \u003cstrong\u003eSIL 3\u003c\/strong\u003e (IEC 61508:2010) and \u003cstrong\u003ePL e\u003c\/strong\u003e (EN ISO 13849-1:2015), meeting the highest industrial safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Output Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Output Current:\u003c\/strong\u003e \u003cstrong\u003e0.5 A per channel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Nominal Current:\u003c\/strong\u003e \u003cstrong\u003e2 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Detection:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOutput current \u003cstrong\u003e\u0026lt;10 mA\u003c\/strong\u003e: \"CurrentOK\" = \u003cstrong\u003eFALSE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput current \u003cstrong\u003e10 to 50 mA\u003c\/strong\u003e: \"CurrentOK\" = \u003cstrong\u003eUndefined\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput current \u003cstrong\u003e\u0026gt;50 mA\u003c\/strong\u003e: \"CurrentOK\" = \u003cstrong\u003eTRUE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBraking Voltage for Inductive Loads:\u003c\/strong\u003e Maximum \u003cstrong\u003e90 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switching Frequency:\u003c\/strong\u003e Refer to \"Inrush Current Behavior for Output Channels\" in the user manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Test Pulse Length:\u003c\/strong\u003e \u003cstrong\u003e500 µs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Time Between Two Test Pulses:\u003c\/strong\u003e \u003cstrong\u003e49.5 ms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Capacitance:\u003c\/strong\u003e \u003cstrong\u003e100 nF\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation Between Channel and Bus:\u003c\/strong\u003e \u003cstrong\u003e500 Veff\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal Mounting:\u003c\/strong\u003e \u003cstrong\u003e0 to 60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical Mounting:\u003c\/strong\u003e \u003cstrong\u003e0 to 50°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e \u003cstrong\u003e5% to 95%, non-condensing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e \u003cstrong\u003eIP20\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UKCA, cULus FSPC E361559, ATEX Zone 2, DNV, CCS, LR, KR, ABS, BV, KC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Safe control of actuators such as \u003cstrong\u003erelays and valves\u003c\/strong\u003e in \u003cstrong\u003eindustrial automation systems requiring high functional safety\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Systems:\u003c\/strong\u003e Implementation in \u003cstrong\u003esystems requiring strict monitoring and reliable fail-safe responses\u003c\/strong\u003e to ensure operational integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Control:\u003c\/strong\u003e Safe shutdown of \u003cstrong\u003ecritical machine components\u003c\/strong\u003e, protecting operators and equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Industries:\u003c\/strong\u003e Used in \u003cstrong\u003echemical, petrochemical, and pharmaceutical sectors\u003c\/strong\u003e, where \u003cstrong\u003esafety and precise actuator control\u003c\/strong\u003e are essential.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong\u003eWhy Choose the B\u0026amp;R X20SO4110?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eB\u0026amp;R X20SO4110\u003c\/strong\u003e is a \u003cstrong\u003erobust and reliable solution\u003c\/strong\u003e for applications demanding \u003cstrong\u003ehigh-level functional safety\u003c\/strong\u003e. With features such as \u003cstrong\u003ecurrent monitoring, open circuit detection, and compliance with SIL 3 and PL e standards\u003c\/strong\u003e, this module ensures \u003cstrong\u003esafe and efficient operation in critical industrial environments\u003c\/strong\u003e. Its \u003cstrong\u003eseamless integration into existing systems\u003c\/strong\u003e and \u003cstrong\u003ecertified safety compliance\u003c\/strong\u003e make it an \u003cstrong\u003eideal choice\u003c\/strong\u003e for companies looking to \u003cstrong\u003emaximize safety and operational efficiency\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e","brand":"Flateck Automation","offers":[{"title":"Refurbished","offer_id":48872033812707,"sku":"Refurbished","price":750.0,"currency_code":"USD","in_stock":true},{"title":"DDPARTSSOLUTION Packaging","offer_id":48872033845475,"sku":"DDPARTSSOLUTION Packaging","price":1140.0,"currency_code":"USD","in_stock":true},{"title":"Original Packaging","offer_id":48872033878243,"sku":"Original Packaging","price":1870.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/X20SO4110.png?v=1777119946","url":"https:\/\/flateck.myshopify.com\/products\/x20so4110-b-r-digital-output-module-designed-for-industrial-automation-featuring-reliable-performance-compact-design-and-diagnostic-leds-for-efficient-control-and-monitoring","provider":"Flateck Automation","version":"1.0","type":"link"}