{"product_id":"pepperl-fuchs-kcd2-sr-ex2-185533-2-channel-namur-switch-amplifier","title":"Pepperl+Fuchs KCD2-SR-Ex2 (185533)","description":"\u003cp\u003eThe \u003cstrong\u003eKCD2-SR-Ex2 (185533)\u003c\/strong\u003e by \u003cstrong\u003ePepperl+Fuchs\u003c\/strong\u003e is a \u003cstrong\u003e2-channel isolated switch amplifier\u003c\/strong\u003e designed to interface with \u003cstrong\u003eNAMUR-type inductive sensors\u003c\/strong\u003e or \u003cstrong\u003emechanical contacts\u003c\/strong\u003e located in hazardous areas. It transfers binary signals safely to control systems in the safe area, providing \u003cstrong\u003erelay contact outputs\u003c\/strong\u003e for reliable switching.\u003c\/p\u003e\n\u003cp\u003eThis device operates on \u003cstrong\u003e24V DC\u003c\/strong\u003e and features \u003cstrong\u003eSIL 2 (SC 3)\u003c\/strong\u003e certification according to \u003cstrong\u003eIEC\/EN 61508\u003c\/strong\u003e, making it ideal for safety-critical and general-purpose automation applications. It is suitable for use with proximity sensors and other field devices that require intrinsic safety.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 185533\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e NAMUR sensors or mechanical contacts (Zone 0\/1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Relay contact (2 SPDT relays)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e 2 isolated channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC (via Power Rail or terminals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail, 12.5 mm housing width\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 2 (SC 3)\u003c\/strong\u003e – Certified per IEC\/EN 61508\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Fault Detection:\u003c\/strong\u003e Short circuit and open circuit monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e 3-way isolation between input, output, and power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus LEDs:\u003c\/strong\u003e Input\/output indicators for diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e KCD2-SR-Ex2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 185533\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e NAMUR (IEC 60947-5-6)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e 2 x SPDT relay contacts (max. 250 V AC \/ 2 A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V DC (19.2–30 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e ≤ 1 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;10 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Width:\u003c\/strong\u003e 12.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e –20 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e ATEX, IECEx, UL, SIL2, CE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Signal Transfer\u003c\/strong\u003e – From NAMUR inductive sensors to control rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntrinsic Safety Circuits\u003c\/strong\u003e – Zone 0\/1 compatible field device connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomation Systems\u003c\/strong\u003e – Input isolation for PLC\/DCS integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL-Compliant Installations\u003c\/strong\u003e – Process safety applications requiring SIL 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose the KCD2-SR-Ex2 (185533)?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTwo-channel operation with compact DIN housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCertified for SIL 2 applications with diagnostic monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrusted performance for NAMUR proximity sensors in Ex zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast integration with Power Rail and safe area controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882178457827,"sku":"KCD2-SR-Ex2","price":165.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/KCD2-SR-Ex2.webp?v=1777373262","url":"https:\/\/flateck.myshopify.com\/products\/pepperl-fuchs-kcd2-sr-ex2-185533-2-channel-namur-switch-amplifier","provider":"Flateck Automation","version":"1.0","type":"link"}