{"product_id":"pepperl-fuchs-kcd2-sld-ex1-1245-solenoid-driver-12-v-dc-sil-3-intrinsically-safe","title":"Pepperl+Fuchs KCD2-SLD-Ex1.1245","description":"\u003cp\u003eThe \u003cstrong\u003eKCD2-SLD-Ex1.1245\u003c\/strong\u003e is a \u003cstrong\u003esingle-channel isolated barrier solenoid driver\u003c\/strong\u003e designed to safely control \u003cstrong\u003esolenoids, LEDs, and audible alarms\u003c\/strong\u003e in \u003cstrong\u003ehazardous environments\u003c\/strong\u003e. It delivers up to \u003cstrong\u003e45 mA at 12 V DC\u003c\/strong\u003e to field devices and is certified for \u003cstrong\u003eSIL 3 functional safety\u003c\/strong\u003e, ensuring reliable performance in critical process automation applications.\u003c\/p\u003e\n\u003cp\u003eIt accepts either \u003cstrong\u003eloop-powered\u003c\/strong\u003e or \u003cstrong\u003elogic-level input signals\u003c\/strong\u003e, offers \u003cstrong\u003eline fault transparency (LFT)\u003c\/strong\u003e, and is \u003cstrong\u003eimmune to test pulses\u003c\/strong\u003e, making it ideal for advanced safety systems.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Power:\u003c\/strong\u003e 12 V DC, 45 mA nominal (current-limited to 50 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLoop-powered: 19–30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogic-level: 15–30 V DC (5 mA max), 0–5 V = OFF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≤ 20 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL Rating:\u003c\/strong\u003e SIL 3 per IEC\/EN 61508 \/ 61511\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Fault Transparency (LFT):\u003c\/strong\u003e Fault status shown in field\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTest Pulse Immunity:\u003c\/strong\u003e Compatible with diagnostic pulse systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e Short-circuit and overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (12.5 mm width)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indication:\u003c\/strong\u003e Front LED indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e KCD2-SLD-Ex1.1245\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V DC (19–30 V range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e Approx. 12 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Load:\u003c\/strong\u003e 45 mA (50 mA current limit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 12.5 mm (W) × 119 mm (H) × 115 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing:\u003c\/strong\u003e Compact design, IP20 rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas\u003c\/strong\u003e – Solenoid actuation in ATEX\/IECEx zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Processing\u003c\/strong\u003e – Intrinsically safe power to field alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIS Systems\u003c\/strong\u003e – SIL 3-compliant actuation of final elements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Automation\u003c\/strong\u003e – Reliable powering of indicators and sounders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose the KCD2-SLD-Ex1.1245?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible input options for loop or logic control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable 12 V DC power delivery for field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in safety diagnostics and fault transparency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSIL 3 certified for high-integrity safety loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact DIN rail installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882176557283,"sku":"KCD2-SLD-Ex1.1245","price":1080.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/KCD2-SLD-Ex1.1245.webp?v=1777373237","url":"https:\/\/flateck.myshopify.com\/products\/pepperl-fuchs-kcd2-sld-ex1-1245-solenoid-driver-12-v-dc-sil-3-intrinsically-safe","provider":"Flateck Automation","version":"1.0","type":"link"}