{"product_id":"pepperl-fuchs-kcd2-scd-ex1-316911-1-channel-smart-current-driver-sil-2","title":"Pepperl+Fuchs KCD2-SCD-Ex1","description":"\u003cp\u003eThe \u003cstrong\u003ePepperl+Fuchs KCD2-SCD-Ex1 (316911)\u003c\/strong\u003e is a \u003cstrong\u003e1-channel isolated SMART current driver\u003c\/strong\u003e, designed to drive \u003cstrong\u003eI\/P converters, control valves, and other actuators\u003c\/strong\u003e in hazardous areas. It accepts a \u003cstrong\u003e4–20 mA analog signal\u003c\/strong\u003e from the safe area and transmits it into the hazardous area with \u003cstrong\u003eHART signal compatibility\u003c\/strong\u003e, while maintaining \u003cstrong\u003eintrinsic safety\u003c\/strong\u003e and \u003cstrong\u003eSIL 2 compliance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis unit ensures reliable and precise signal transmission for demanding process automation tasks, offering \u003cstrong\u003egalvanic isolation\u003c\/strong\u003e, \u003cstrong\u003efault monitoring\u003c\/strong\u003e, and \u003cstrong\u003eDIN rail mounting\u003c\/strong\u003e in a \u003cstrong\u003ecompact 12.5 mm housing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 316911\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Direction:\u003c\/strong\u003e Safe area → Hazardous area\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e Intrinsically safe 4–20 mA (drives I\/P converters, control valves)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e 4–20 mA from safe area\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Compatible:\u003c\/strong\u003e Passes through HART communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 2 (SC 3)\u003c\/strong\u003e Certified – per IEC\/EN 61508\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Fault Detection:\u003c\/strong\u003e Monitoring for open\/short circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC (via terminals or Power Rail)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (12.5 mm housing width)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Status and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e KCD2-SCD-Ex1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMFG Item Number:\u003c\/strong\u003e 316911\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4–20 mA, intrinsically safe (Ex ia)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 20 to 30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e Approx. 0.9 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Width:\u003c\/strong\u003e 12.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e –20 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e SIL 2, SC 3 (IEC\/EN 61508)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e ATEX, IECEx, UL, CSA, CE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Valve Operation\u003c\/strong\u003e – Safe current drive to field actuators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/P Converters\u003c\/strong\u003e – Signal transmission in hazardous zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDCS Integration\u003c\/strong\u003e – Seamless current control from control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical and Oil \u0026amp; Gas Industries\u003c\/strong\u003e – SIL-compliant actuator driving\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Loop Systems\u003c\/strong\u003e – Digital signal transparency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003eWhy Choose the KCD2-SCD-Ex1 (316911)?:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSIL 2 certified for safety-critical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable, safe signal transmission to Ex field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHART communication support for smart diagnostics and tuning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and DIN rail friendly for panel space optimization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48882178228451,"sku":"KCD2-SCD-Ex1","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/KCD2-SCD-Ex1.webp?v=1777373256","url":"https:\/\/flateck.myshopify.com\/products\/pepperl-fuchs-kcd2-scd-ex1-316911-1-channel-smart-current-driver-sil-2","provider":"Flateck Automation","version":"1.0","type":"link"}