{"product_id":"beckhoff-el4014-analog-output-terminal","title":"Beckhoff EL4014","description":"\u003cp data-end=\"727\" data-start=\"409\"\u003eThe \u003cstrong data-end=\"432\" data-start=\"413\"\u003eBeckhoff EL4014\u003c\/strong\u003e is a \u003cstrong data-end=\"474\" data-start=\"438\"\u003e4-channel analog output terminal\u003c\/strong\u003e that generates voltage signals in the range of \u003cstrong data-end=\"532\" data-start=\"522\"\u003e0–10 V\u003c\/strong\u003e with \u003cstrong data-end=\"559\" data-start=\"538\"\u003e12-bit resolution\u003c\/strong\u003e. It is optimized for precise signal generation, making it suitable for actuator control, setpoint specification, and automation processes in industrial environments.\u003c\/p\u003e\n\u003ch3 data-end=\"751\" data-start=\"729\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"749\" data-start=\"733\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"985\" data-start=\"752\"\u003e\n\u003cli data-end=\"780\" data-start=\"752\"\u003e\n\u003cp data-end=\"780\" data-start=\"754\"\u003e4 analog output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"805\" data-start=\"781\"\u003e\n\u003cp data-end=\"805\" data-start=\"783\"\u003eOutput range: 0–10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"848\" data-start=\"806\"\u003e\n\u003cp data-end=\"848\" data-start=\"808\"\u003e12-bit resolution for accurate control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"902\" data-start=\"849\"\u003e\n\u003cp data-end=\"902\" data-start=\"851\"\u003eElectrical isolation between field and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"942\" data-start=\"903\"\u003e\n\u003cp data-end=\"942\" data-start=\"905\"\u003eCompact and modular DIN-rail design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"985\" data-start=\"943\"\u003e\n\u003cp data-end=\"985\" data-start=\"945\"\u003eDiagnostic LEDs for operational status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1021\" data-start=\"987\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1019\" data-start=\"991\"\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1410\" data-start=\"1022\"\u003e\n\u003cli data-end=\"1051\" data-start=\"1022\"\u003e\n\u003cp data-end=\"1051\" data-start=\"1024\"\u003e\u003cstrong data-end=\"1042\" data-start=\"1024\"\u003eBeckhoff Code:\u003c\/strong\u003e EL4014\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1088\" data-start=\"1052\"\u003e\n\u003cp data-end=\"1088\" data-start=\"1054\"\u003e\u003cstrong data-end=\"1063\" data-start=\"1054\"\u003eType:\u003c\/strong\u003e Analog Output Terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1108\" data-start=\"1089\"\u003e\n\u003cp data-end=\"1108\" data-start=\"1091\"\u003e\u003cstrong data-end=\"1104\" data-start=\"1091\"\u003eChannels:\u003c\/strong\u003e 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1145\" data-start=\"1109\"\u003e\n\u003cp data-end=\"1145\" data-start=\"1111\"\u003e\u003cstrong data-end=\"1136\" data-start=\"1111\"\u003eOutput Voltage Range:\u003c\/strong\u003e 0–10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1172\" data-start=\"1146\"\u003e\n\u003cp data-end=\"1172\" data-start=\"1148\"\u003e\u003cstrong data-end=\"1163\" data-start=\"1148\"\u003eResolution:\u003c\/strong\u003e 12-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1220\" data-start=\"1173\"\u003e\n\u003cp data-end=\"1220\" data-start=\"1175\"\u003e\u003cstrong data-end=\"1206\" data-start=\"1175\"\u003eOutput Current per Channel:\u003c\/strong\u003e up to 10 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1272\" data-start=\"1221\"\u003e\n\u003cp data-end=\"1272\" data-start=\"1223\"\u003e\u003cstrong data-end=\"1258\" data-start=\"1223\"\u003eCurrent Consumption (from bus):\u003c\/strong\u003e typ. 140 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1306\" data-start=\"1273\"\u003e\n\u003cp data-end=\"1306\" data-start=\"1275\"\u003e\u003cstrong data-end=\"1300\" data-start=\"1275\"\u003eElectrical Isolation:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1352\" data-start=\"1307\"\u003e\n\u003cp data-end=\"1352\" data-start=\"1309\"\u003e\u003cstrong data-end=\"1335\" data-start=\"1309\"\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1379\" data-start=\"1353\"\u003e\n\u003cp data-end=\"1379\" data-start=\"1355\"\u003e\u003cstrong data-end=\"1368\" data-start=\"1355\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1410\" data-start=\"1380\"\u003e\n\u003cp data-end=\"1410\" data-start=\"1382\"\u003e\u003cstrong data-end=\"1401\" data-start=\"1382\"\u003eCertifications:\u003c\/strong\u003e CE, UL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1434\" data-start=\"1412\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1432\" data-start=\"1416\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1640\" data-start=\"1435\"\u003e\n\u003cli data-end=\"1470\" data-start=\"1435\"\u003e\n\u003cp data-end=\"1470\" data-start=\"1437\"\u003eControl of actuators and drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1517\" data-start=\"1471\"\u003e\n\u003cp data-end=\"1517\" data-start=\"1473\"\u003eProcess automation and setpoint generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1555\" data-start=\"1518\"\u003e\n\u003cp data-end=\"1555\" data-start=\"1520\"\u003eMachine and plant control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1590\" data-start=\"1556\"\u003e\n\u003cp data-end=\"1590\" data-start=\"1558\"\u003eMeasurement and test equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1640\" data-start=\"1591\"\u003e\n\u003cp data-end=\"1640\" data-start=\"1593\"\u003eIntegration in Beckhoff EtherCAT I\/O networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1679\" data-start=\"1642\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1677\" data-start=\"1646\"\u003eWhy Choose Beckhoff EL4014?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1859\" data-start=\"1680\"\u003e\n\u003cli data-end=\"1721\" data-start=\"1680\"\u003e\n\u003cp data-end=\"1721\" data-start=\"1682\"\u003eProvides 4 independent analog outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1762\" data-start=\"1722\"\u003e\n\u003cp data-end=\"1762\" data-start=\"1724\"\u003eHigh accuracy with 12-bit resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1803\" data-start=\"1763\"\u003e\n\u003cp data-end=\"1803\" data-start=\"1765\"\u003eReliable and compact for modular use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1859\" data-start=\"1804\"\u003e\n\u003cp data-end=\"1859\" data-start=\"1806\"\u003eFully compatible with Beckhoff EtherCAT I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48872044364003,"sku":"EL4014","price":826.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/EL4014.webp?v=1777120952","url":"https:\/\/flateck.myshopify.com\/products\/beckhoff-el4014-analog-output-terminal","provider":"Flateck Automation","version":"1.0","type":"link"}