{"product_id":"allen-bradley-1746-nt4-thermocouple-mv-analog-input-module-slc-500","title":"Allen-Bradley 1746-NT4","description":"\u003cdiv class=\"markdown markdown-main-panel response-optimization\" id=\"model-response-message-contentr_6f447c6b28fecf44\" dir=\"ltr\"\u003e\n\u003cp data-sourcepos=\"17:1-17:592\"\u003eThe Allen-Bradley 1746-NT4 is an analog input module designed for use in SLC 500 programmable logic controller (PLC) systems. This module provides eight differential input channels capable of accepting a wide range of thermocouple and millivolt (mV) signals, making it suitable for temperature monitoring and other analog measurement applications. It is compatible with SLC 5\/03 and SLC 5\/04 processors, offering flexibility for various system configurations. This module is commonly used in industrial automation for processes involving temperature control, monitoring, and data acquisition.\u003c\/p\u003e\n\u003cp data-sourcepos=\"19:1-19:17\"\u003e\u003cstrong\u003e◆Key Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"21:1-28:0\"\u003e\n\u003cli data-sourcepos=\"21:1-21:106\"\u003e\n\u003cstrong\u003e8 Differential Input Channels:\u003c\/strong\u003e Allows for connection of up to eight separate analog input signals.\u003c\/li\u003e\n\u003cli data-sourcepos=\"22:1-22:128\"\u003e\n\u003cstrong\u003eThermocouple Input:\u003c\/strong\u003e Accepts various thermocouple types (J, K, T, E, R, S, B, N, C) for accurate temperature measurement.\u003c\/li\u003e\n\u003cli data-sourcepos=\"23:1-23:87\"\u003e\n\u003cstrong\u003eMillivolt (mV) Input:\u003c\/strong\u003e Supports mV signals for other analog sensor applications.\u003c\/li\u003e\n\u003cli data-sourcepos=\"24:1-24:84\"\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Provides accurate and precise analog-to-digital conversion.\u003c\/li\u003e\n\u003cli data-sourcepos=\"25:1-25:86\"\u003e\n\u003cstrong\u003eSLC 500 Compatibility:\u003c\/strong\u003e Designed for use with SLC 5\/03 and SLC 5\/04 processors.\u003c\/li\u003e\n\u003cli data-sourcepos=\"26:1-26:68\"\u003e\n\u003cstrong\u003eRemovable Terminal Block:\u003c\/strong\u003e Simplifies wiring and maintenance.\u003c\/li\u003e\n\u003cli data-sourcepos=\"27:1-28:0\"\u003e\n\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e Provides accurate temperature readings by compensating for ambient temperature changes at the thermocouple connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"29:1-29:102\"\u003e\u003cstrong\u003e◆Technical Specifications (Consult official Rockwell Automation documentation for precise details):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"31:1-42:0\"\u003e\n\u003cli data-sourcepos=\"31:1-31:41\"\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Module\u003c\/li\u003e\n\u003cli data-sourcepos=\"32:1-32:32\"\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e 1746-NT4\u003c\/li\u003e\n\u003cli data-sourcepos=\"33:1-33:40\"\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 8 Differential\u003c\/li\u003e\n\u003cli data-sourcepos=\"34:1-34:65\"\u003e\n\u003cstrong\u003eInput Types:\u003c\/strong\u003e Thermocouple (J, K, T, E, R, S, B, N, C), mV\u003c\/li\u003e\n\u003cli data-sourcepos=\"35:1-35:84\"\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e (Specify ranges for each thermocouple type and mV if available)\u003c\/li\u003e\n\u003cli data-sourcepos=\"36:1-36:54\"\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e (Specify resolution in bits or mV)\u003c\/li\u003e\n\u003cli data-sourcepos=\"37:1-37:67\"\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e (Specify accuracy for thermocouple and mV inputs)\u003c\/li\u003e\n\u003cli data-sourcepos=\"38:1-38:44\"\u003e\n\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e Built-in\u003c\/li\u003e\n\u003cli data-sourcepos=\"39:1-39:76\"\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e (Specify current draw from the SLC 500 backplane)\u003c\/li\u003e\n\u003cli data-sourcepos=\"40:1-40:68\"\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e (Specify operating temperature range)\u003c\/li\u003e\n\u003cli data-sourcepos=\"41:1-42:0\"\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e (Specify dimensions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"43:1-43:17\"\u003e\u003cstrong\u003e◆Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"45:1-50:0\"\u003e\n\u003cli data-sourcepos=\"45:1-45:38\"\u003eTemperature Monitoring and Control\u003c\/li\u003e\n\u003cli data-sourcepos=\"46:1-46:19\"\u003eProcess Control\u003c\/li\u003e\n\u003cli data-sourcepos=\"47:1-47:20\"\u003eData Acquisition\u003c\/li\u003e\n\u003cli data-sourcepos=\"48:1-48:28\"\u003eEnvironmental Monitoring\u003c\/li\u003e\n\u003cli data-sourcepos=\"49:1-50:0\"\u003eIndustrial Automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"51:1-51:28\"\u003e\u003cstrong\u003e◆Why Choose the 1746-NT4?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"53:1-58:0\"\u003e\n\u003cli data-sourcepos=\"53:1-53:125\"\u003e\n\u003cstrong\u003eReliable Temperature Measurement:\u003c\/strong\u003e Provides accurate and stable temperature readings using various thermocouple types.\u003c\/li\u003e\n\u003cli data-sourcepos=\"54:1-54:98\"\u003e\n\u003cstrong\u003eVersatile Analog Input:\u003c\/strong\u003e Accepts both thermocouple and mV signals for diverse applications.\u003c\/li\u003e\n\u003cli data-sourcepos=\"55:1-55:92\"\u003e\n\u003cstrong\u003eSLC 500 System Integration:\u003c\/strong\u003e Seamlessly integrates into existing SLC 500 PLC systems.\u003c\/li\u003e\n\u003cli data-sourcepos=\"56:1-56:109\"\u003e\n\u003cstrong\u003eCost-Effective Solution:\u003c\/strong\u003e Offers a cost-effective way to add analog input capabilities to your system.\u003c\/li\u003e\n\u003cli data-sourcepos=\"57:1-58:0\"\u003e\n\u003cstrong\u003eIndustry Standard:\u003c\/strong\u003e Widely used and trusted in industrial automation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48840707408099,"sku":null,"price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/1746-NT4.webp?v=1776625921","url":"https:\/\/flateck.myshopify.com\/products\/allen-bradley-1746-nt4-thermocouple-mv-analog-input-module-slc-500","provider":"Flateck Automation","version":"1.0","type":"link"}