{"product_id":"allen-bradley-1734-ie4s","title":"Allen-Bradley 1734-IE4S","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IE4S\u003c\/strong\u003e\u003cspan\u003e is a \u003c\/span\u003e\u003cstrong\u003e4-channel analog input module\u003c\/strong\u003e\u003cspan\u003e designed for \u003c\/span\u003e\u003cstrong\u003ePOINT Guard I\/O safety applications\u003c\/strong\u003e\u003cspan\u003e. It supports \u003c\/span\u003e\u003cstrong\u003emultiple input signal types\u003c\/strong\u003e\u003cspan\u003e, including \u003c\/span\u003e\u003cstrong\u003ecurrent (4-20mA, 0-20mA), voltage (±5V, ±10V, 0-5V, 0-10V), and tachometer inputs (0-24V, 1-1000Hz)\u003c\/strong\u003e\u003cspan\u003e. This module enables \u003c\/span\u003e\u003cstrong\u003eprecise safety monitoring of analog signals\u003c\/strong\u003e\u003cspan\u003e in applications requiring \u003c\/span\u003e\u003cstrong\u003efunctional safety compliance\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"821\" data-end=\"1056\"\u003e\u003cstrong\u003e🔹 Key Features:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-Channel Analog Input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Supports multiple\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent, voltage, and tachometer inputs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Isolated Design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eefficient safety monitoring\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20mA, 0-20mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±5V, ±10V, 0-5V, 0-10V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0-24V, configurable in 1V increments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Frequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1-1000Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for Safety Applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Meets\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efunctional safety requirements\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePOINT Guard I\/O Compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Seamlessly integrates into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRockwell Automation safety system\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e🔹 Technical Specifications:\u003c\/strong\u003e\u003cstrong data-start=\"1083\" data-end=\"1096\"\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1734-IE4S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAnalog (Current, Voltage, Tachometer)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 Channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20mA, 0-20mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±5V, ±10V, 0-5V, 0-10V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0-24V (configurable in 1V increments)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Frequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1-1000Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIN Rail\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT Guard I\/O\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e🔹 Applications:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety Systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog safety monitoring\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Safety Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time monitoring of critical parameters\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Control \u0026amp; Automation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Enhances\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety in hazardous environments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCADA \u0026amp; Distributed Safety I\/O Systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecise data acquisition and fault detection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e🔹 Why Choose the \u003c\/strong\u003e\u003cstrong\u003eAllen-Bradley 1734-IE4S?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IE4S POINT Guard I\/O Safety Analog Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-accuracy analog signal monitoring\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple input range options\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseamless safety system integration\u003c\/strong\u003e, making it an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eideal choice for safety-critical industrial automation\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48838370033891,"sku":null,"price":1339.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/Allen-Bradley1734-IE4S.webp?v=1776505681","url":"https:\/\/flateck.myshopify.com\/products\/allen-bradley-1734-ie4s","provider":"Flateck Automation","version":"1.0","type":"link"}