{"product_id":"abb-ot160e4-molded-case-circuit-breaker-mccb","title":"ABB OT160E4","description":"\u003ch1 data-end=\"138\" data-start=\"82\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"136\" data-start=\"84\"\u003eABB OT160E4 | Molded Case Circuit Breaker (MCCB)\u003c\/strong\u003e\n\u003c\/h1\u003e\n\n\u003cp data-end=\"983\" data-start=\"403\"\u003eThe \u003cstrong data-end=\"422\" data-start=\"407\"\u003eABB OT160E4\u003c\/strong\u003e is a \u003cstrong data-end=\"466\" data-start=\"428\"\u003emolded case circuit breaker (MCCB)\u003c\/strong\u003e designed for \u003cstrong data-end=\"492\" data-start=\"480\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-end=\"525\" data-start=\"497\"\u003eshort circuit protection\u003c\/strong\u003e in \u003cstrong data-end=\"543\" data-start=\"529\"\u003eindustrial\u003c\/strong\u003e and \u003cstrong data-end=\"581\" data-start=\"548\"\u003ecommercial electrical systems\u003c\/strong\u003e. With a \u003cstrong data-end=\"612\" data-start=\"590\"\u003e160A rated current\u003c\/strong\u003e, this breaker provides \u003cstrong data-end=\"659\" data-start=\"636\"\u003ereliable protection\u003c\/strong\u003e for circuits carrying significant power loads. Its \u003cstrong data-end=\"739\" data-start=\"711\"\u003eadjustable trip settings\u003c\/strong\u003e and \u003cstrong data-end=\"770\" data-start=\"744\"\u003ehigh breaking capacity\u003c\/strong\u003e make it suitable for various applications in \u003cstrong data-end=\"846\" data-start=\"816\"\u003epower distribution systems\u003c\/strong\u003e and \u003cstrong data-end=\"876\" data-start=\"851\"\u003emotor control centers\u003c\/strong\u003e. The \u003cstrong data-end=\"893\" data-start=\"882\"\u003eOT160E4\u003c\/strong\u003e ensures \u003cstrong data-end=\"926\" data-start=\"902\"\u003eefficient protection\u003c\/strong\u003e and \u003cstrong data-end=\"956\" data-start=\"931\"\u003elong-term reliability\u003c\/strong\u003e in demanding environments.\u003c\/p\u003e\n\u003ch2 data-end=\"1006\" data-start=\"985\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1004\" data-start=\"988\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"1609\" data-start=\"1007\"\u003e\n\u003cli data-end=\"1033\" data-start=\"1007\"\u003e\n\u003cstrong data-end=\"1019\" data-start=\"1009\"\u003eModel:\u003c\/strong\u003e ABB OT160E4\u003c\/li\u003e\n\u003cli data-end=\"1132\" data-start=\"1034\"\u003e\n\u003cstrong data-end=\"1049\" data-start=\"1036\"\u003eFunction:\u003c\/strong\u003e \u003cstrong data-end=\"1088\" data-start=\"1050\"\u003eMolded case circuit breaker (MCCB)\u003c\/strong\u003e for overload and short circuit protection\u003c\/li\u003e\n\u003cli data-end=\"1160\" data-start=\"1133\"\u003e\n\u003cstrong data-end=\"1153\" data-start=\"1135\"\u003eRated Current:\u003c\/strong\u003e 160A\u003c\/li\u003e\n\u003cli data-end=\"1259\" data-start=\"1161\"\u003e\n\u003cstrong data-end=\"1192\" data-start=\"1163\"\u003eAdjustable Trip Settings:\u003c\/strong\u003e Provides customizable protection for different load requirements\u003c\/li\u003e\n\u003cli data-end=\"1301\" data-start=\"1260\"\u003e\n\u003cstrong data-end=\"1284\" data-start=\"1262\"\u003eBreaking Capacity:\u003c\/strong\u003e 36kA (at 415V)\u003c\/li\u003e\n\u003cli data-end=\"1424\" data-start=\"1302\"\u003e\n\u003cstrong data-end=\"1340\" data-start=\"1304\"\u003eThermal and Magnetic Protection:\u003c\/strong\u003e Provides fast and reliable protection against \u003cstrong data-end=\"1399\" data-start=\"1387\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-end=\"1422\" data-start=\"1404\"\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1512\" data-start=\"1425\"\u003e\n\u003cstrong data-end=\"1446\" data-start=\"1427\"\u003eCompact Design:\u003c\/strong\u003e Ideal for \u003cstrong data-end=\"1480\" data-start=\"1457\"\u003epanel installations\u003c\/strong\u003e and \u003cstrong data-end=\"1510\" data-start=\"1485\"\u003emotor control centers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1609\" data-start=\"1513\"\u003e\n\u003cstrong data-end=\"1540\" data-start=\"1515\"\u003eReliable Performance:\u003c\/strong\u003e Designed for \u003cstrong data-end=\"1578\" data-start=\"1554\"\u003elong-term durability\u003c\/strong\u003e and \u003cstrong data-end=\"1607\" data-start=\"1583\"\u003econsistent operation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1641\" data-start=\"1611\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1639\" data-start=\"1614\"\u003eTechnical Information\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"1888\" data-start=\"1642\"\u003e\n\u003cli data-end=\"1672\" data-start=\"1642\"\u003e\n\u003cstrong data-end=\"1662\" data-start=\"1644\"\u003eRated Voltage:\u003c\/strong\u003e 400V AC\u003c\/li\u003e\n\u003cli data-end=\"1714\" data-start=\"1673\"\u003e\n\u003cstrong data-end=\"1697\" data-start=\"1675\"\u003eBreaking Capacity:\u003c\/strong\u003e 36kA (at 415V)\u003c\/li\u003e\n\u003cli data-end=\"1754\" data-start=\"1715\"\u003e\n\u003cstrong data-end=\"1735\" data-start=\"1717\"\u003eTripping Type:\u003c\/strong\u003e Thermal-magnetic\u003c\/li\u003e\n\u003cli data-end=\"1790\" data-start=\"1755\"\u003e\n\u003cstrong data-end=\"1775\" data-start=\"1757\"\u003eMounting Type:\u003c\/strong\u003e \u003cstrong data-end=\"1788\" data-start=\"1776\"\u003eDIN rail\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1834\" data-start=\"1791\"\u003e\n\u003cstrong data-end=\"1819\" data-start=\"1793\"\u003eOperating Temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli data-end=\"1865\" data-start=\"1835\"\u003e\n\u003cstrong data-end=\"1858\" data-start=\"1837\"\u003eProtection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli data-end=\"1888\" data-start=\"1866\"\u003e\n\u003cstrong data-end=\"1879\" data-start=\"1868\"\u003eWeight:\u003c\/strong\u003e 5.1 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1911\" data-start=\"1890\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1909\" data-start=\"1893\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"2360\" data-start=\"1912\"\u003e\n\u003cli data-end=\"2030\" data-start=\"1912\"\u003e\n\u003cstrong data-end=\"1948\" data-start=\"1914\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e Protects circuits and equipment in \u003cstrong data-end=\"1997\" data-start=\"1984\"\u003efactories\u003c\/strong\u003e, \u003cstrong data-end=\"2009\" data-start=\"1999\"\u003eplants\u003c\/strong\u003e, and \u003cstrong data-end=\"2028\" data-start=\"2015\"\u003emachinery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2158\" data-start=\"2031\"\u003e\n\u003cstrong data-end=\"2058\" data-start=\"2033\"\u003eCommercial Buildings:\u003c\/strong\u003e Ensures protection for electrical systems in \u003cstrong data-end=\"2115\" data-start=\"2104\"\u003eoffices\u003c\/strong\u003e, \u003cstrong data-end=\"2127\" data-start=\"2117\"\u003eretail\u003c\/strong\u003e spaces, and \u003cstrong data-end=\"2156\" data-start=\"2140\"\u003edata centers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2262\" data-start=\"2159\"\u003e\n\u003cstrong data-end=\"2187\" data-start=\"2161\"\u003eMotor Control Centers:\u003c\/strong\u003e Ideal for \u003cstrong data-end=\"2218\" data-start=\"2198\"\u003emotor protection\u003c\/strong\u003e in \u003cstrong data-end=\"2236\" data-start=\"2222\"\u003eautomation\u003c\/strong\u003e and \u003cstrong data-end=\"2260\" data-start=\"2241\"\u003econtrol systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2360\" data-start=\"2263\"\u003e\n\u003cstrong data-end=\"2282\" data-start=\"2265\"\u003eHVAC Systems:\u003c\/strong\u003e Safeguards \u003cstrong data-end=\"2305\" data-start=\"2294\"\u003eheating\u003c\/strong\u003e, \u003cstrong data-end=\"2322\" data-start=\"2307\"\u003eventilation\u003c\/strong\u003e, and \u003cstrong data-end=\"2348\" data-start=\"2328\"\u003eair conditioning\u003c\/strong\u003e equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2379\" data-start=\"2362\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"2377\" data-start=\"2365\"\u003eBenefits\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"2723\" data-start=\"2380\"\u003e\n\u003cli data-end=\"2479\" data-start=\"2380\"\u003e\n\u003cstrong data-end=\"2406\" data-start=\"2382\"\u003eReliable Protection:\u003c\/strong\u003e Safeguards circuits from \u003cstrong data-end=\"2444\" data-start=\"2432\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-end=\"2466\" data-start=\"2449\"\u003eshort circuit\u003c\/strong\u003e conditions\u003c\/li\u003e\n\u003cli data-end=\"2574\" data-start=\"2480\"\u003e\n\u003cstrong data-end=\"2508\" data-start=\"2482\"\u003eCustomizable Settings:\u003c\/strong\u003e Adjustable protection settings for a wide range of applications\u003c\/li\u003e\n\u003cli data-end=\"2642\" data-start=\"2575\"\u003e\n\u003cstrong data-end=\"2606\" data-start=\"2577\"\u003eCompact and Space-Saving:\u003c\/strong\u003e Ideal for \u003cstrong data-end=\"2640\" data-start=\"2617\"\u003epanel installations\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2723\" data-start=\"2643\"\u003e\n\u003cstrong data-end=\"2668\" data-start=\"2645\"\u003eDurable and Robust:\u003c\/strong\u003e Built to withstand \u003cstrong data-end=\"2721\" data-start=\"2688\"\u003eharsh industrial environments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2913\" data-start=\"2725\"\u003eThe \u003cstrong data-end=\"2744\" data-start=\"2729\"\u003eABB OT160E4\u003c\/strong\u003e is a \u003cstrong data-end=\"2781\" data-start=\"2750\"\u003emolded case circuit breaker\u003c\/strong\u003e providing \u003cstrong data-end=\"2815\" data-start=\"2792\"\u003esuperior protection\u003c\/strong\u003e for \u003cstrong data-end=\"2834\" data-start=\"2820\"\u003eindustrial\u003c\/strong\u003e and \u003cstrong data-end=\"2872\" data-start=\"2839\"\u003ecommercial electrical systems\u003c\/strong\u003e, ensuring \u003cstrong data-end=\"2893\" data-start=\"2883\"\u003esafety\u003c\/strong\u003e and \u003cstrong data-end=\"2912\" data-start=\"2898\"\u003eefficiency\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003chr\u003e\n\n\u003chr\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48871980957923,"sku":"OT160E4","price":1123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/OT160E4.webp?v=1777118360","url":"https:\/\/flateck.myshopify.com\/products\/abb-ot160e4-molded-case-circuit-breaker-mccb","provider":"Flateck Automation","version":"1.0","type":"link"}