{"product_id":"abb-ot160e3-air-circuit-breaker-acb","title":"ABB OT160E3","description":"\u003ch1 data-end=\"129\" data-start=\"82\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"127\" data-start=\"84\"\u003eABB OT160E3 | Air Circuit Breaker (ACB)\u003c\/strong\u003e\n\u003c\/h1\u003e\n\n\u003cp data-end=\"878\" data-start=\"375\"\u003eThe \u003cstrong data-end=\"394\" data-start=\"379\"\u003eABB OT160E3\u003c\/strong\u003e is a high-performance \u003cstrong data-end=\"446\" data-start=\"417\"\u003eair circuit breaker (ACB)\u003c\/strong\u003e designed to protect electrical circuits from \u003cstrong data-end=\"504\" data-start=\"492\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-end=\"526\" data-start=\"509\"\u003eshort circuit\u003c\/strong\u003e conditions. With a \u003cstrong data-end=\"568\" data-start=\"546\"\u003e160A rated current\u003c\/strong\u003e, it provides reliable protection for \u003cstrong data-end=\"620\" data-start=\"606\"\u003eindustrial\u003c\/strong\u003e and \u003cstrong data-end=\"658\" data-start=\"625\"\u003ecommercial electrical systems\u003c\/strong\u003e. The \u003cstrong data-end=\"675\" data-start=\"664\"\u003eOT160E3\u003c\/strong\u003e features \u003cstrong data-end=\"713\" data-start=\"685\"\u003eadjustable trip settings\u003c\/strong\u003e, \u003cstrong data-end=\"733\" data-start=\"715\"\u003ecompact design\u003c\/strong\u003e, and \u003cstrong data-end=\"760\" data-start=\"739\"\u003eeasy installation\u003c\/strong\u003e, making it suitable for \u003cstrong data-end=\"815\" data-start=\"785\"\u003epower distribution systems\u003c\/strong\u003e, \u003cstrong data-end=\"842\" data-start=\"817\"\u003emotor control centers\u003c\/strong\u003e, and \u003cstrong data-end=\"877\" data-start=\"848\"\u003eautomated control systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-end=\"901\" data-start=\"880\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"899\" data-start=\"883\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"1451\" data-start=\"902\"\u003e\n\u003cli data-end=\"928\" data-start=\"902\"\u003e\n\u003cstrong data-end=\"914\" data-start=\"904\"\u003eModel:\u003c\/strong\u003e ABB OT160E3\u003c\/li\u003e\n\u003cli data-end=\"1018\" data-start=\"929\"\u003e\n\u003cstrong data-end=\"944\" data-start=\"931\"\u003eFunction:\u003c\/strong\u003e \u003cstrong data-end=\"974\" data-start=\"945\"\u003eAir circuit breaker (ACB)\u003c\/strong\u003e for overload and short circuit protection\u003c\/li\u003e\n\u003cli data-end=\"1046\" data-start=\"1019\"\u003e\n\u003cstrong data-end=\"1039\" data-start=\"1021\"\u003eRated Current:\u003c\/strong\u003e 160A\u003c\/li\u003e\n\u003cli data-end=\"1088\" data-start=\"1047\"\u003e\n\u003cstrong data-end=\"1071\" data-start=\"1049\"\u003eBreaking Capacity:\u003c\/strong\u003e 36kA (at 415V)\u003c\/li\u003e\n\u003cli data-end=\"1171\" data-start=\"1089\"\u003e\n\u003cstrong data-end=\"1120\" data-start=\"1091\"\u003eAdjustable Trip Settings:\u003c\/strong\u003e Customizable protection for various system loads\u003c\/li\u003e\n\u003cli data-end=\"1275\" data-start=\"1172\"\u003e\n\u003cstrong data-end=\"1210\" data-start=\"1174\"\u003eThermal and Magnetic Protection:\u003c\/strong\u003e Reliable protection against \u003cstrong data-end=\"1251\" data-start=\"1239\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-end=\"1273\" data-start=\"1256\"\u003eshort circuit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1377\" data-start=\"1276\"\u003e\n\u003cstrong data-end=\"1297\" data-start=\"1278\"\u003eCompact Design:\u003c\/strong\u003e Space-saving for easy integration into control panels and distribution boards\u003c\/li\u003e\n\u003cli data-end=\"1451\" data-start=\"1378\"\u003e\n\u003cstrong data-end=\"1402\" data-start=\"1380\"\u003eEasy Installation:\u003c\/strong\u003e Designed for \u003cstrong data-end=\"1434\" data-start=\"1416\"\u003equick mounting\u003c\/strong\u003e and easy setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1483\" data-start=\"1453\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1481\" data-start=\"1456\"\u003eTechnical Information\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"1705\" data-start=\"1484\"\u003e\n\u003cli data-end=\"1514\" data-start=\"1484\"\u003e\n\u003cstrong data-end=\"1504\" data-start=\"1486\"\u003eRated Voltage:\u003c\/strong\u003e 415V AC\u003c\/li\u003e\n\u003cli data-end=\"1556\" data-start=\"1515\"\u003e\n\u003cstrong data-end=\"1539\" data-start=\"1517\"\u003eBreaking Capacity:\u003c\/strong\u003e 36kA (at 415V)\u003c\/li\u003e\n\u003cli data-end=\"1596\" data-start=\"1557\"\u003e\n\u003cstrong data-end=\"1577\" data-start=\"1559\"\u003eTripping Type:\u003c\/strong\u003e Thermal-magnetic\u003c\/li\u003e\n\u003cli data-end=\"1637\" data-start=\"1597\"\u003e\n\u003cstrong data-end=\"1617\" data-start=\"1599\"\u003eMounting Type:\u003c\/strong\u003e \u003cstrong data-end=\"1635\" data-start=\"1618\"\u003ePanel mounted\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1681\" data-start=\"1638\"\u003e\n\u003cstrong data-end=\"1666\" data-start=\"1640\"\u003eOperating Temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli data-end=\"1705\" data-start=\"1682\"\u003e\n\u003cstrong data-end=\"1695\" data-start=\"1684\"\u003eWeight:\u003c\/strong\u003e 10.6 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1728\" data-start=\"1707\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1726\" data-start=\"1710\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"2161\" data-start=\"1729\"\u003e\n\u003cli data-end=\"1833\" data-start=\"1729\"\u003e\n\u003cstrong data-end=\"1765\" data-start=\"1731\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e Protects circuits in \u003cstrong data-end=\"1800\" data-start=\"1787\"\u003efactories\u003c\/strong\u003e, \u003cstrong data-end=\"1812\" data-start=\"1802\"\u003eplants\u003c\/strong\u003e, and \u003cstrong data-end=\"1831\" data-start=\"1818\"\u003emachinery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1966\" data-start=\"1834\"\u003e\n\u003cstrong data-end=\"1861\" data-start=\"1836\"\u003eCommercial Buildings:\u003c\/strong\u003e Provides protection for \u003cstrong data-end=\"1908\" data-start=\"1886\"\u003eelectrical systems\u003c\/strong\u003e in \u003cstrong data-end=\"1923\" data-start=\"1912\"\u003eoffices\u003c\/strong\u003e, \u003cstrong data-end=\"1941\" data-start=\"1925\"\u003edata centers\u003c\/strong\u003e, and \u003cstrong data-end=\"1964\" data-start=\"1947\"\u003eretail spaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2054\" data-start=\"1967\"\u003e\n\u003cstrong data-end=\"1995\" data-start=\"1969\"\u003eMotor Control Centers:\u003c\/strong\u003e Ideal for protecting \u003cstrong data-end=\"2027\" data-start=\"2017\"\u003emotors\u003c\/strong\u003e in \u003cstrong data-end=\"2052\" data-start=\"2031\"\u003eautomated systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2161\" data-start=\"2055\"\u003e\n\u003cstrong data-end=\"2080\" data-start=\"2057\"\u003ePower Distribution:\u003c\/strong\u003e Suitable for \u003cstrong data-end=\"2123\" data-start=\"2094\"\u003ehigh-current applications\u003c\/strong\u003e in industrial and commercial setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2180\" data-start=\"2163\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"2178\" data-start=\"2166\"\u003eBenefits\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"2601\" data-start=\"2181\"\u003e\n\u003cli data-end=\"2300\" data-start=\"2181\"\u003e\n\u003cstrong data-end=\"2207\" data-start=\"2183\"\u003eReliable Protection:\u003c\/strong\u003e Ensures \u003cstrong data-end=\"2234\" data-start=\"2216\"\u003esafe operation\u003c\/strong\u003e by preventing damage due to \u003cstrong data-end=\"2275\" data-start=\"2263\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-end=\"2298\" data-start=\"2280\"\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2399\" data-start=\"2301\"\u003e\n\u003cstrong data-end=\"2329\" data-start=\"2303\"\u003eCustomizable Settings:\u003c\/strong\u003e Adjustable protection tailored to the needs of various applications\u003c\/li\u003e\n\u003cli data-end=\"2487\" data-start=\"2400\"\u003e\n\u003cstrong data-end=\"2428\" data-start=\"2402\"\u003eDurable and Efficient:\u003c\/strong\u003e Built to last, offering reliable \u003cstrong data-end=\"2485\" data-start=\"2462\"\u003elong-term operation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2601\" data-start=\"2488\"\u003e\n\u003cstrong data-end=\"2511\" data-start=\"2490\"\u003eEasy Integration:\u003c\/strong\u003e \u003cstrong data-end=\"2530\" data-start=\"2512\"\u003eCompact design\u003c\/strong\u003e and \u003cstrong data-end=\"2557\" data-start=\"2535\"\u003equick installation\u003c\/strong\u003e simplify integration into control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2835\" data-start=\"2603\"\u003eThe \u003cstrong data-end=\"2622\" data-start=\"2607\"\u003eABB OT160E3\u003c\/strong\u003e is a highly reliable \u003cstrong data-end=\"2673\" data-start=\"2644\"\u003eair circuit breaker (ACB)\u003c\/strong\u003e designed to provide \u003cstrong data-end=\"2715\" data-start=\"2694\"\u003erobust protection\u003c\/strong\u003e for \u003cstrong data-end=\"2734\" data-start=\"2720\"\u003eindustrial\u003c\/strong\u003e and \u003cstrong data-end=\"2772\" data-start=\"2739\"\u003ecommercial electrical systems\u003c\/strong\u003e, ensuring \u003cstrong data-end=\"2803\" data-start=\"2783\"\u003elong-term safety\u003c\/strong\u003e and \u003cstrong data-end=\"2834\" data-start=\"2808\"\u003eoperational efficiency\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003chr\u003e\n\n\u003chr\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48871980368099,"sku":"OT160E3","price":710.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/OT160E3.webp?v=1777118347","url":"https:\/\/flateck.myshopify.com\/products\/abb-ot160e3-air-circuit-breaker-acb","provider":"Flateck Automation","version":"1.0","type":"link"}