{"product_id":"abb-f204-residual-current-circuit-breaker-rccb","title":"ABB F204","description":"\u003ch1 data-end=\"139\" data-start=\"81\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"137\" data-start=\"83\"\u003eABB F204 | Residual Current Circuit Breaker (RCCB)\u003c\/strong\u003e\n\u003c\/h1\u003e\n\n\u003cp data-end=\"910\" data-start=\"435\"\u003eThe \u003cstrong data-end=\"451\" data-start=\"439\"\u003eABB F204\u003c\/strong\u003e is a \u003cstrong data-end=\"500\" data-start=\"457\"\u003eresidual current circuit breaker (RCCB)\u003c\/strong\u003e designed to detect and interrupt leakage currents, preventing \u003cstrong data-end=\"599\" data-start=\"563\"\u003eelectric shocks and fire hazards\u003c\/strong\u003e caused by ground faults. With a \u003cstrong data-end=\"652\" data-start=\"632\"\u003efour-pole design\u003c\/strong\u003e, it ensures \u003cstrong data-end=\"693\" data-start=\"665\"\u003ecomprehensive protection\u003c\/strong\u003e in \u003cstrong data-end=\"731\" data-start=\"697\"\u003ethree-phase electrical systems\u003c\/strong\u003e. Engineered for \u003cstrong data-end=\"783\" data-start=\"748\"\u003ehigh reliability and durability\u003c\/strong\u003e, the \u003cstrong data-end=\"797\" data-start=\"789\"\u003eF204\u003c\/strong\u003e is ideal for \u003cstrong data-end=\"867\" data-start=\"811\"\u003eresidential, commercial, and industrial applications\u003c\/strong\u003e, meeting international safety standards.\u003c\/p\u003e\n\u003ch2 data-end=\"933\" data-start=\"912\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"931\" data-start=\"915\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"1483\" data-start=\"934\"\u003e\n\u003cli data-end=\"957\" data-start=\"934\"\u003e\n\u003cstrong data-end=\"946\" data-start=\"936\"\u003eModel:\u003c\/strong\u003e ABB F204\u003c\/li\u003e\n\u003cli data-end=\"1050\" data-start=\"958\"\u003e\n\u003cstrong data-end=\"973\" data-start=\"960\"\u003eFunction:\u003c\/strong\u003e \u003cstrong data-end=\"1017\" data-start=\"974\"\u003eResidual current circuit breaker (RCCB)\u003c\/strong\u003e for leakage current protection\u003c\/li\u003e\n\u003cli data-end=\"1080\" data-start=\"1051\"\u003e\n\u003cstrong data-end=\"1063\" data-start=\"1053\"\u003ePoles:\u003c\/strong\u003e 4P (Four-pole)\u003c\/li\u003e\n\u003cli data-end=\"1166\" data-start=\"1081\"\u003e\n\u003cstrong data-end=\"1101\" data-start=\"1083\"\u003eRated Current:\u003c\/strong\u003e Available in multiple ratings (e.g., 25A, 40A, 63A, 80A, 100A)\u003c\/li\u003e\n\u003cli data-end=\"1226\" data-start=\"1167\"\u003e\n\u003cstrong data-end=\"1190\" data-start=\"1169\"\u003eSensitivity (Δn):\u003c\/strong\u003e 30mA, 100mA, 300mA, 500mA options\u003c\/li\u003e\n\u003cli data-end=\"1291\" data-start=\"1227\"\u003e\n\u003cstrong data-end=\"1247\" data-start=\"1229\"\u003eTripping Type:\u003c\/strong\u003e AC, A, or B type depending on the variant\u003c\/li\u003e\n\u003cli data-end=\"1349\" data-start=\"1292\"\u003e\n\u003cstrong data-end=\"1313\" data-start=\"1294\"\u003eCompact Design:\u003c\/strong\u003e Optimized for panel installations\u003c\/li\u003e\n\u003cli data-end=\"1420\" data-start=\"1350\"\u003e\n\u003cstrong data-end=\"1376\" data-start=\"1352\"\u003eQuick Disconnection:\u003c\/strong\u003e Ensures fast response to leakage currents\u003c\/li\u003e\n\u003cli data-end=\"1483\" data-start=\"1421\"\u003e\n\u003cstrong data-end=\"1442\" data-start=\"1423\"\u003eIEC Compliance:\u003c\/strong\u003e Meets \u003cstrong data-end=\"1464\" data-start=\"1449\"\u003eIEC 61008-1\u003c\/strong\u003e safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1515\" data-start=\"1485\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1513\" data-start=\"1488\"\u003eTechnical Information\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"1793\" data-start=\"1516\"\u003e\n\u003cli data-end=\"1550\" data-start=\"1516\"\u003e\n\u003cstrong data-end=\"1536\" data-start=\"1518\"\u003eRated Voltage:\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n\u003cli data-end=\"1588\" data-start=\"1551\"\u003e\n\u003cstrong data-end=\"1575\" data-start=\"1553\"\u003eBreaking Capacity:\u003c\/strong\u003e Up to 10kA\u003c\/li\u003e\n\u003cli data-end=\"1616\" data-start=\"1589\"\u003e\n\u003cstrong data-end=\"1605\" data-start=\"1591\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-end=\"1648\" data-start=\"1617\"\u003e\n\u003cstrong data-end=\"1637\" data-start=\"1619\"\u003eMounting Type:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli data-end=\"1693\" data-start=\"1649\"\u003e\n\u003cstrong data-end=\"1677\" data-start=\"1651\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to 55°C\u003c\/li\u003e\n\u003cli data-end=\"1747\" data-start=\"1694\"\u003e\n\u003cstrong data-end=\"1722\" data-start=\"1696\"\u003eMechanical Durability:\u003c\/strong\u003e Over 10,000 operations\u003c\/li\u003e\n\u003cli data-end=\"1793\" data-start=\"1748\"\u003e\n\u003cstrong data-end=\"1771\" data-start=\"1750\"\u003eProtection Class:\u003c\/strong\u003e IP20 (internal use)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1816\" data-start=\"1795\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1814\" data-start=\"1798\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"2161\" data-start=\"1817\"\u003e\n\u003cli data-end=\"1901\" data-start=\"1817\"\u003e\n\u003cstrong data-end=\"1845\" data-start=\"1819\"\u003eResidential Buildings:\u003c\/strong\u003e Ensures \u003cstrong data-end=\"1875\" data-start=\"1854\"\u003eelectrical safety\u003c\/strong\u003e in homes and apartments\u003c\/li\u003e\n\u003cli data-end=\"1996\" data-start=\"1902\"\u003e\n\u003cstrong data-end=\"1930\" data-start=\"1904\"\u003eCommercial Facilities:\u003c\/strong\u003e Protects \u003cstrong data-end=\"1994\" data-start=\"1940\"\u003eoffice spaces, retail stores, and public buildings\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2085\" data-start=\"1997\"\u003e\n\u003cstrong data-end=\"2028\" data-start=\"1999\"\u003eIndustrial Installations:\u003c\/strong\u003e Enhances \u003cstrong data-end=\"2083\" data-start=\"2038\"\u003esafety in electrical distribution systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2161\" data-start=\"2086\"\u003e\n\u003cstrong data-end=\"2105\" data-start=\"2088\"\u003eData Centers:\u003c\/strong\u003e Prevents damage to \u003cstrong data-end=\"2159\" data-start=\"2125\"\u003esensitive electronic equipment\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2180\" data-start=\"2163\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"2178\" data-start=\"2166\"\u003eBenefits\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"2485\" data-start=\"2181\"\u003e\n\u003cli data-end=\"2256\" data-start=\"2181\"\u003e\n\u003cstrong data-end=\"2214\" data-start=\"2183\"\u003eEnhanced Electrical Safety:\u003c\/strong\u003e Prevents electric shocks and fire risks\u003c\/li\u003e\n\u003cli data-end=\"2338\" data-start=\"2257\"\u003e\n\u003cstrong data-end=\"2284\" data-start=\"2259\"\u003eReliable Performance:\u003c\/strong\u003e Ensures fast and accurate leakage current detection\u003c\/li\u003e\n\u003cli data-end=\"2415\" data-start=\"2339\"\u003e\n\u003cstrong data-end=\"2374\" data-start=\"2341\"\u003eFlexible Sensitivity Options:\u003c\/strong\u003e Available for various protection needs\u003c\/li\u003e\n\u003cli data-end=\"2485\" data-start=\"2416\"\u003e\n\u003cstrong data-end=\"2440\" data-start=\"2418\"\u003eEasy Installation:\u003c\/strong\u003e Compact and \u003cstrong data-end=\"2483\" data-start=\"2453\"\u003eDIN rail-compatible design\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2660\" data-start=\"2487\"\u003eThe \u003cstrong data-end=\"2503\" data-start=\"2491\"\u003eABB F204\u003c\/strong\u003e is a \u003cstrong data-end=\"2560\" data-start=\"2509\"\u003etrusted solution for leakage current protection\u003c\/strong\u003e, offering \u003cstrong data-end=\"2613\" data-start=\"2571\"\u003ehigh performance and safety compliance\u003c\/strong\u003e across \u003cstrong data-end=\"2657\" data-start=\"2621\"\u003evarious electrical installations\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003chr\u003e\n\n\u003chr\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48871981777123,"sku":"F204","price":1032.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/F204.webp?v=1777118377","url":"https:\/\/flateck.myshopify.com\/products\/abb-f204-residual-current-circuit-breaker-rccb","provider":"Flateck Automation","version":"1.0","type":"link"}