{"product_id":"abb-ach550-uh-125a-4-3aua0000014483-100-hp-hvac-drive-480-v-125-a-nema-1-enclosure","title":"ABB ACH550-UH-125A-4 | 3AUA0000014483","description":"\u003ch2 class=\"\" data-end=\"186\" data-start=\"107\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"186\" data-start=\"110\"\u003eABB ACH550-UH-125A-4 | 100 HP HVAC Drive, 480 V, 125 A, NEMA 1 Enclosure\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp class=\"\" data-end=\"401\" data-start=\"188\"\u003e\u003cstrong data-end=\"216\" data-start=\"188\"\u003eGlobal Commercial Alias:\u003c\/strong\u003e ACH550-UH-125A-4\u003cstrong data-end=\"251\" data-start=\"236\"\u003eProduct ID:\u003c\/strong\u003e \u003cspan\u003e3AUA0000014483\u003c\/span\u003e\u003cstrong data-end=\"294\" data-start=\"269\"\u003eABB Type Designation:\u003c\/strong\u003e ACH550-UH-125A-4\u003cstrong data-end=\"338\" data-start=\"314\"\u003eCatalog Description:\u003c\/strong\u003e HVAC AC Drive, 3-phase, 100 HP, 125 A, 480 V, NEMA 1 enclosure\u003c\/p\u003e\n\n\u003cp class=\"\" data-end=\"668\" data-start=\"421\"\u003eThe \u003cstrong data-end=\"449\" data-start=\"425\"\u003eABB ACH550-UH-125A-4\u003c\/strong\u003e is a high-performance variable frequency drive designed for demanding HVAC applications. Supporting 100 HP motors, it ensures efficient, reliable control of fans, pumps, and ventilation systems in commercial buildings.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"690\" data-start=\"670\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"690\" data-start=\"674\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1187\" data-start=\"692\"\u003e\n\u003cli class=\"\" data-end=\"727\" data-start=\"692\"\u003e\n\u003cp class=\"\" data-end=\"727\" data-start=\"694\"\u003e\u003cstrong data-end=\"710\" data-start=\"694\"\u003eMotor Power:\u003c\/strong\u003e 75 kW (100 HP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"772\" data-start=\"728\"\u003e\n\u003cp class=\"\" data-end=\"772\" data-start=\"730\"\u003e\u003cstrong data-end=\"748\" data-start=\"730\"\u003eInput Voltage:\u003c\/strong\u003e 380–480 V AC, 3-phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"802\" data-start=\"773\"\u003e\n\u003cp class=\"\" data-end=\"802\" data-start=\"775\"\u003e\u003cstrong data-end=\"794\" data-start=\"775\"\u003eOutput Current:\u003c\/strong\u003e 125 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"839\" data-start=\"803\"\u003e\n\u003cp class=\"\" data-end=\"839\" data-start=\"805\"\u003e\u003cstrong data-end=\"825\" data-start=\"805\"\u003eFrequency Range:\u003c\/strong\u003e 0 to 500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"888\" data-start=\"840\"\u003e\n\u003cp class=\"\" data-end=\"888\" data-start=\"842\"\u003e\u003cstrong data-end=\"860\" data-start=\"842\"\u003eControl Modes:\u003c\/strong\u003e V\/f and sensorless vector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"935\" data-start=\"889\"\u003e\n\u003cp class=\"\" data-end=\"935\" data-start=\"891\"\u003e\u003cstrong data-end=\"913\" data-start=\"891\"\u003eOverload Capacity:\u003c\/strong\u003e 110% for 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"981\" data-start=\"936\"\u003e\n\u003cp class=\"\" data-end=\"981\" data-start=\"938\"\u003e\u003cstrong data-end=\"953\" data-start=\"938\"\u003eEMC Filter:\u003c\/strong\u003e Integrated, C2 compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1027\" data-start=\"982\"\u003e\n\u003cp class=\"\" data-end=\"1027\" data-start=\"984\"\u003e\u003cstrong data-end=\"1003\" data-start=\"984\"\u003eSafety Feature:\u003c\/strong\u003e Safe Torque Off (STO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1072\" data-start=\"1028\"\u003e\n\u003cp class=\"\" data-end=\"1072\" data-start=\"1030\"\u003e\u003cstrong data-end=\"1051\" data-start=\"1030\"\u003eFieldbus Support:\u003c\/strong\u003e BACnet, Modbus, N2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1118\" data-start=\"1073\"\u003e\n\u003cp class=\"\" data-end=\"1118\" data-start=\"1075\"\u003e\u003cstrong data-end=\"1094\" data-start=\"1075\"\u003eUser Interface:\u003c\/strong\u003e Dedicated HVAC keypad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1161\" data-start=\"1119\"\u003e\n\u003cp class=\"\" data-end=\"1161\" data-start=\"1121\"\u003e\u003cstrong data-end=\"1140\" data-start=\"1121\"\u003eEnclosure Type:\u003c\/strong\u003e NEMA 1 (UL Type 1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1187\" data-start=\"1162\"\u003e\n\u003cp class=\"\" data-end=\"1187\" data-start=\"1164\"\u003e\u003cstrong data-end=\"1176\" data-start=\"1164\"\u003eCooling:\u003c\/strong\u003e Forced air\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1221\" data-start=\"1189\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1221\" data-start=\"1193\"\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1564\" data-start=\"1223\"\u003e\n\u003cli class=\"\" data-end=\"1261\" data-start=\"1223\"\u003e\n\u003cp class=\"\" data-end=\"1261\" data-start=\"1225\"\u003e\u003cstrong data-end=\"1242\" data-start=\"1225\"\u003eModel Number:\u003c\/strong\u003e ACH550-UH-125A-4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1295\" data-start=\"1262\"\u003e\n\u003cp class=\"\" data-end=\"1295\" data-start=\"1264\"\u003e\u003cstrong data-end=\"1284\" data-start=\"1264\"\u003eInput Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1320\" data-start=\"1296\"\u003e\n\u003cp class=\"\" data-end=\"1320\" data-start=\"1298\"\u003e\u003cstrong data-end=\"1316\" data-start=\"1298\"\u003eAnalog Inputs:\u003c\/strong\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1346\" data-start=\"1321\"\u003e\n\u003cp class=\"\" data-end=\"1346\" data-start=\"1323\"\u003e\u003cstrong data-end=\"1342\" data-start=\"1323\"\u003eDigital Inputs:\u003c\/strong\u003e 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1372\" data-start=\"1347\"\u003e\n\u003cp class=\"\" data-end=\"1372\" data-start=\"1349\"\u003e\u003cstrong data-end=\"1368\" data-start=\"1349\"\u003eAnalog Outputs:\u003c\/strong\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1397\" data-start=\"1373\"\u003e\n\u003cp class=\"\" data-end=\"1397\" data-start=\"1375\"\u003e\u003cstrong data-end=\"1393\" data-start=\"1375\"\u003eRelay Outputs:\u003c\/strong\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1443\" data-start=\"1398\"\u003e\n\u003cp class=\"\" data-end=\"1443\" data-start=\"1400\"\u003e\u003cstrong data-end=\"1426\" data-start=\"1400\"\u003eOperating Temperature:\u003c\/strong\u003e -10°C to +40°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1500\" data-start=\"1444\"\u003e\n\u003cp class=\"\" data-end=\"1500\" data-start=\"1446\"\u003e\u003cstrong data-end=\"1473\" data-start=\"1446\"\u003eDimensions (H x W x D):\u003c\/strong\u003e 770 mm x 290 mm x 262 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1530\" data-start=\"1501\"\u003e\n\u003cp class=\"\" data-end=\"1530\" data-start=\"1503\"\u003e\u003cstrong data-end=\"1514\" data-start=\"1503\"\u003eWeight:\u003c\/strong\u003e Approx. 35 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1564\" data-start=\"1531\"\u003e\n\u003cp class=\"\" data-end=\"1564\" data-start=\"1533\"\u003e\u003cstrong data-end=\"1552\" data-start=\"1533\"\u003eCertifications:\u003c\/strong\u003e UL, cUL, CE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1586\" data-start=\"1566\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1586\" data-start=\"1570\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1719\" data-start=\"1588\"\u003e\n\u003cli class=\"\" data-end=\"1615\" data-start=\"1588\"\u003e\n\u003cp class=\"\" data-end=\"1615\" data-start=\"1590\"\u003eCommercial HVAC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1649\" data-start=\"1616\"\u003e\n\u003cp class=\"\" data-end=\"1649\" data-start=\"1618\"\u003eAir handlers and exhaust fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1685\" data-start=\"1650\"\u003e\n\u003cp class=\"\" data-end=\"1685\" data-start=\"1652\"\u003ePump control in smart buildings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1719\" data-start=\"1686\"\u003e\n\u003cp class=\"\" data-end=\"1719\" data-start=\"1688\"\u003eVentilation and cooling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1748\" data-start=\"1721\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"1748\" data-start=\"1725\"\u003eProduct Description\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"\" data-end=\"2018\" data-start=\"1750\"\u003eEngineered for performance and efficiency, the ACH550-UH-125A-4 delivers seamless HVAC control in commercial automation systems. Its plug-and-play installation, HVAC features, and integrated fieldbus communication enhance energy efficiency and operational reliability.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"2060\" data-start=\"2020\"\u003e\n\u003cspan style=\"color:#0066CC; font-size:1em;\"\u003e◆ \u003c\/span\u003e\u003cstrong data-end=\"2060\" data-start=\"2024\"\u003eWhy Choose ABB ACH550-UH-125A-4?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"2231\" data-start=\"2062\"\u003e\n\u003cli class=\"\" data-end=\"2105\" data-start=\"2062\"\u003e\n\u003cp class=\"\" data-end=\"2105\" data-start=\"2064\"\u003eOptimized for 100 HP HVAC motor control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2155\" data-start=\"2106\"\u003e\n\u003cp class=\"\" data-end=\"2155\" data-start=\"2108\"\u003eIntegrated HVAC protocols and safety features\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2197\" data-start=\"2156\"\u003e\n\u003cp class=\"\" data-end=\"2197\" data-start=\"2158\"\u003eEasy setup and diagnostics via keypad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2231\" data-start=\"2198\"\u003e\n\u003cp class=\"\" data-end=\"2231\" data-start=\"2200\"\u003eNEMA 1 enclosure for indoor use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Flateck Automation","offers":[{"title":"Default Title","offer_id":48871967391971,"sku":"ACH550-UH-125A-4","price":7012.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/4214\/3203\/files\/ACH550-UH-125A-4.webp?v=1777118186","url":"https:\/\/flateck.myshopify.com\/products\/abb-ach550-uh-125a-4-3aua0000014483-100-hp-hvac-drive-480-v-125-a-nema-1-enclosure","provider":"Flateck Automation","version":"1.0","type":"link"}